User Manual
Table Of Contents
- Chapter 1 Introduction
- Chapter 2 Panels and Connections
- Chapter 3 Getting Started
- Chapter 4 Decoder Configuration and Operation by Web Browser
- 4.1 Decoder Configuration
- 4.1.1 Checking Device Information
- 4.1.2 Configuring Time Settings
- 4.1.3 Configuring RS-485/RS-232 Serial Port
- 4.1.4 Configuring Basic Network Settings
- 4.1.5 Configuring DDNS Settings
- 4.1.6 Configuring Wi-Fi Settings
- 4.1.7 Configuring Stream Settings
- 4.1.8 Configuring Transparent Channel
- 4.1.9 Configuring Synchronous Output Settings
- 4.1.10 Configuring Personalized Settings
- 4.1.11 Managing User Account
- 4.1.12 Importing/Exporting Configuration Files
- 4.1.13 Maintenance
- 4.2 Setting Video Wall Layout
- 4.3 Configuring Decoding Output
- 4.4 Decoding Operation
- 4.1 Decoder Configuration
- Chapter 5 Decoder Configuration and Operation by Client Software
- Chapter 6 Display via Wi-Fi Connection
- Chapter 7 Appendix
HD Video and Audio Decoder User Manual
DS-6900UDI Decoder User Manual
66
1. Log in to the camera via the Web browser.
2. Click Configuration > Advanced Configuration > System > VCA Resource Type to enter
the VCA Resource Type configuration interface.
3. Select Temperature Measurement and Behavior Analysis as the VCA Resource Type.
4. Click Save to save the settings.
Configure temperature measurement. Step 2
1. Click Configuration > Advanced Configuration > Temperature Measurement >
Temperature Measurement Configuration to enter the Temperature Measurement
configuration interface.
Temperature Measurement Configuration Figure 5-35
2. Check the checkboxes of the interface to set the temperature measurement
configurations.
Enable Temperature Measurement: Check the checkbox to enable temperature
measurement function.
Display Temperature Info. on Stream: Check the checkbox to display temperature
information in live view.
Add Original Data on Capture: Check the checkbox to add original data on capture.
Add Original Data on Stream: Check the checkbox to add original data on stream.
3. Select the Data Refresh Interval from 1s to 5s.
4. Select the Unit to display temperature with Degree Celsius (°C)/Degree Fahrenheit
(°F)/Degree Kelvin (K).
5. Configure the Temperature Range.
6. Click Save to save the settings.
Configure the temperature measurement and alarm. Step 3
1. Click Configuration > Advanced Configuration > Temperature Measurement >
Temperature Measurement and Alarm to enter the Temperature Measurement and
Alarm configuration interface.