User Manual

User Manual of Handheld Thermography Camera
21
Interval Alarm
Set the alarm temperature section (e.g.,
90 °C to 150 °C), when target temperature
is within the section (e.g., 100 °C), the
device alarms.
Insulation Alarm
Set the alarm temperature section (e.g.,
90 °C to 120 °C), when target temperature
is without the section (e.g., 70 °C or
125 °C), the device alarms.
5. Press to exit.
Go to Local Settings > Image Settings >Audible Warning. Tap on
to enable audible warning. The device will sound when alarm
is triggered.
This function varies according to different camera models.
5 Picture and Video
Before you start:
Insert memory card into the device, then you can record videos, capture
snapshots, and mark and save important data.
Device does not support capturing or recording when the menu is
shown.
When the device is connected to your PC, it does not support
capturing or recording.
Go to Local Settings > Device Settings > Filename Header. You can
set the filename header for capturing or recording to distinguish the
files recorded in a specify scene.
5.1 Capture Picture
You can set the Flashlight Setting ON/OFF if required.
Go to Local Settings > Image > Picture Resolution to set the
resolution of optical image if required.
Steps:
1. Select Local Settings (
) from the main menu.
2. Go to Local Settings > Camera Settings > Trigger Settings.