User Manual
Table Of Contents
User Manual of Handheld Thermography Camera
18
frame on touchscreen to enlarge or contract the
frame.
5. Press OK. The Max. Temperature, Low Temperature,
and Average Temperature of frame (e.g. S1) displays
S1 Max: XX Min: XX Avg: XX.
6. Repeat step 1 to 5 to set other frames.
At most three frames supported.
4.3.4 Delete Rules
Tap
and press OK to clear all temperature rules.
Or tap
and choose the single rule you want to delete
to delete it.
4.4 Set Black Body Temperature Calibration
You need to purchase black body according to your need. Skip this step
if the device is not equipped with black body. This function varies
according to different camera models.
If black body is installed around the device, setting the black body
temperature calibration can improve the temperature measurement
accuracy.
Go to Settings > Local Settings > Thermography Settings > Black Body
Temperature Calibration > Calibration Mode. Both auto calibration and
manual calibration are selectable. You can also turn this function off.
4.4.1 Auto Calibration
Steps: