Handheld Thermography Camera User Manual
User Manual of Handheld Thermography Camera © 2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons.
User Manual of Handheld Thermography Camera YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS.
User Manual of Handheld Thermography Camera This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2.
User Manual of Handheld Thermography Camera Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
User Manual of Handheld Thermography Camera Symbol Description Indicates a hazard with a high level of risk, which if not avoided, will result in death or serious injury. Safety Instructions These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. Laws and Regulations ● Use of the product must be in strict compliance with the local electrical safety regulations.
User Manual of Handheld Thermography Camera ● DO NOT swallow the battery to avoid chemical burns. ● DO NOT place the battery in the reach of children. Maintenance ● Clean the lens with soft and dry cloth or wiping paper to avoid scratching it. ● Wipe the device gently with a clean cloth and a small quantity of ethanol, if ● If the product does not work properly, please contact your dealer or the nearest necessary. service center.
User Manual of Handheld Thermography Camera Scan the QR code to view the user manual on your mobile phone. Note that mobile data charges may apply if Wi-Fi is unavailable.
User Manual of Handheld Thermography Camera Table of Contents 1 Overview .............................................................................................. 1 1.1 1.2 1.3 2 Device Description ..................................................................................... 1 Main Functions ......................................................................................... 1 Appearance ...............................................................................................
User Manual of Handheld Thermography Camera 7 HIKMICRO Viewer APP Connection ...................................................... 25 7.1 7.2 8 Maintenance....................................................................................... 27 8.1 8.2 8.3 9 Connect via Wi-Fi .................................................................................... 25 Connect via Hot Spot................................................................................ 26 View Device Information ...........
User Manual of Handheld Thermography Camera 1 Overview 1.1 Device Description The handheld thermography camera is a device with both optical images and thermal images. It can realize thermography, video recording, snapshot capturing, alarm. It can connect to Wi-Fi, hotspot, and Bluetooth. The built-in high-sensitivity IR detector and high-performance sensor detect the variation of temperature and measure the real-time temperature.
User Manual of Handheld Thermography Camera This function varies according to different camera models. Palette and Alarm Device supports multiple palettes, and you can set the palette mode according to the alarm function. Client Software Connection You can connect the device with HIKMICRO Viewer APP via Wi-Fi or hot spot to view live view, capture, and recording, etc. on your phone. You can connect the device with HIKMICRO Analyzer to analyze the thermography pictures captured by devices.
User Manual of Handheld Thermography Camera 1.3 Appearance Audio LED Indicator Loudspeaker Touch Screen Lens Sheet ON/OFF Laser (Reserved) Back Navigation Focus Knob Lens Cover Thermal Lens Tripod Interface Trigger LED Light (Reserved) Laser (Reserved) Optical Lens Battery Component Laser Button Navigation Button Lens Sheet Button Back Button Focus Knob Cable Interface SD Card Slot Function Reserved. Menu Button: Press ▽, △, ▷, and ◁ to select parameters. Press OK to confirm.
User Manual of Handheld Thermography Camera Component Trigger Cable Interface Function Pulls the trigger to record videos or capture snapshots. Connects the device to your PC via cable to export files. 2 Preparation 2.1 Charge Device 2.1.1 Charge Device via Cable Interface Before you start: Please make sure the battery is installed before charging. Steps: 1. Open the top cover of the device. 2. Connect the interface and the power adaptor with Type-C cable. Type-C Interface 2.1.
User Manual of Handheld Thermography Camera Battery Steps: 1. Hold the device, and press both battery lock catches of the device. See figure below. Battery Lock Catch Handheld Camera Battery Base 2. Hold the lock catches, and draw the battery base to take out the battery. See figure below.
User Manual of Handheld Thermography Camera 3. Insert the battery into the charging base. See figure below. You can see the charging status via the pilot lamp on the charging base. Battery Charging Base Front View Side View 4. When the battery is fully charged, draw the battery from the charging base. 5. Align the ribbed piece on battery with the notch of the device, and insert battery into the device. See figure below.
User Manual of Handheld Thermography Camera 2.2 Power On/Off Power On button for over three seconds Remove the lens cover, and hold the to turn on the device. You can observe the target when the interface of the device is stable. It may take at least 30 s until the device is ready for using when you power on it. Power Off When the monocular is turned on, hold the seconds to power off the device. button for three 2.2.
User Manual of Handheld Thermography Camera Button control Press the navigation buttons to configure the device. - 2.4 Press the △, ▽, ▷, and ◁ to move the cursor up/down/right/left. Press OK to confirm. Menu Description In the observation interface, tap the screen or press OK to show the menu bar. See figure below.
User Manual of Handheld Thermography Camera 3 Display Settings 3.1 Focus Lens Before you start: Adjust the lens focal length properly before any other configuration, or it may affect the image display and temperature accuracy. Steps: 1. Power on the device. 2. Aim the device lens to the appropriate scene. 3. Adjust the focus knob clockwise or anticlockwise. See figure below.
User Manual of Handheld Thermography Camera DO NOT touch the lens to avoid affecting the display effect. 3.2 Set Screen Brightness Go to Local Settings ( ) > Device Settings > Display Brightness to set the screen brightness. It can be set as Low, Medium, or High. 3.3 Set Display Mode Purpose: You can set the thermal/optical view of the device. Thermal, Fusion, PIP, and Optical are selectable. Steps: 1. Select the Thermal/Optical Settings ( menu. 2. Tap the icons to select a view mode.
User Manual of Handheld Thermography Camera Fusion Level. This function varies according to different camera models. 3. 3.4 Press PIP In PIP (Picture in Picture) mode, the device displays thermal view inside the optical view. You can tap in live view and press ▷ and ◁ to adjust PIP proportion. Or you can adjust it in Settings > Image Settings > PIP proportion. Optical In optical mode, the device displays the optical view. to exit.
User Manual of Handheld Thermography Camera 4. 3.5 Press Red Hot The hot part is red-colored in view. Fusion The hot part is yellow-colored and the cold part is purple-colored in view. Rain The hot part in the image is colored, and the else is blue. to exit the setting interface. Adjust Digital Zoom In the live view interface, press ▽ to adjust the digital zoom to 1×, 2×, or 4×. Then you can view the target or scene in larger size. 3.
User Manual of Handheld Thermography Camera Steps: 1. Select Local Settings ( 2. Select Thermography Settings. ) from the main menu. Set thermography range, emissivity, distance, background temperature, reflection temperature, humidity, and black body temperature calibration. Thermography Range Select the thermography range. The device can detect the temperature and switch thermography range automatically in Auto Switch mode.
User Manual of Handheld Thermography Camera Distance The straight-line distance between the target and the device. You can customize the target distance according to your needs. Background Temperature The average temperature of the environment. Reflection Temperature If any object (not the target) of high temperature is in the scene, and the target emissivity is low, set the reflection temperature as the high temperature to correct the thermography effect.
User Manual of Handheld Thermography Camera 1) Select Auto ( 2) Press OK to confirm. The device adjusts temperature ). difference and temperature range parameters automatically. Manual Adjustment: 1) Select Manual ( 2) Press OK to confirm. The color-temperature bar ). displays. 3) Press ▷ to enlarge the temperature section range (e.g. temperature range changes from 20 °C - 40 °C to 19 °C - 41 °C), or press ◁ to narrow the temperature range. 4) Press △ to move the temperature section higher (e.
User Manual of Handheld Thermography Camera 4.3.1 Set Point Rule You can set Center Point Thermography, High-Temperature Point, Low-Temperature Point, and Custom Point Thermography. Center Point Thermography System detects the temperature of the center. and the temperature (center of view) displays Cen: Tap XX. High-Temperature Point System locates the point of the highest temperature. and the temperature (Highest temperature of Tap view) displays Max: XX.
User Manual of Handheld Thermography Camera 4. Press OK to confirm. The temperature of custom point (e.g. P1) displays P1: XX. 5. Repeat step 1 to 3 to set other custom points. At most ten custom points supported. 4.3.2 Set Line Rule Steps: on the interface. 1. Choose 2. Press OK to generate a default line. 3. Press the △, ▽, ▷, and ◁ to move the line up/down/left/right. 4. Drag points of the line on the touch-screen to extend or shorten the line. 5. Press OK. The Max.
User Manual of Handheld Thermography Camera frame on touchscreen to enlarge or contract the frame. 5. Press OK. The Max. Temperature, Low Temperature, and Average Temperature of frame (e.g. S1) displays S1 Max: XX 6. Min: XX Avg: XX. Repeat step 1 to 5 to set other frames. At most three frames supported. 4.3.4 Delete Rules Tap and press OK to clear all temperature rules. Or tap and choose the single rule you want to delete to delete it. 4.
User Manual of Handheld Thermography Camera 1. Press the △ and ▽ to select Auto and press OK to start auto calibration. 2. Press the △ and ▽ or tap the screen to aim the calibration point at the black body. 3. Press OK to complete calibration. 4.4.2 Manual Calibration Steps: 1. Press the △ and ▽ to select Manual and press OK to start manual calibration.
User Manual of Handheld Thermography Camera 2. Aim the device at the black body and press OK to complete calibration. 4.5 Set Temperature Alarm Before you start: Go to Palettes Settings ( ) to set the palette. Purpose: Set the alarm rules and the device will alarm when the temperature triggers the rule. Steps: 1. Go to Palettes Settings ( 2. Tap on the icons to select an alarm rule type. 3. (Optional) Press the △ and ▽ to select between upper limit and lower limit. 4.
User Manual of Handheld Thermography Camera 5. Press Interval Alarm Set the alarm temperature section (e.g., 90 °C to 150 °C), when target temperature is within the section (e.g., 100 °C), the device alarms. Insulation Alarm Set the alarm temperature section (e.g., 90 °C to 120 °C), when target temperature is without the section (e.g., 70 °C or 125 °C), the device alarms. to exit. • Go to Local Settings > Image Settings >Audible Warning. Tap on • to enable audible warning.
User Manual of Handheld Thermography Camera 3. Select Capture. 4. Press OK. 5. Press 6. In the live view interface, pull the trigger to capture snapshot. The live view freezes and device displays the snapshot editing interface. 7. 1) to exit. Set text remark or voice remark. - Tap to add text remarks. Tap the screen to show the keypad interface, enter the comment and confirm. - Tap to add voice remarks. Hold OK to start recording and release the button to stop recording.
User Manual of Handheld Thermography Camera 5.2 Record Video Steps: 1. Select Local Settings ( 2. Go to Local Settings > Camera Settings > Trigger Settings. 3. Select Record. 4. Press OK. ) from the main menu. You can set the Flashlight Setting ON/OFF if required. 5. 6. Press to exit. In the live view interface, pull the trigger to start recording. The recording icon and count down number display in the interface. 7. When you finish, pull the trigger again to stop recording.
User Manual of Handheld Thermography Camera 2. 3. Press the △, ▽, ▷, and ◁ to select the video or snapshot. Press OK to view the file. 5.4 When you are viewing the videos or capturing snapshots, you can switch the file by tapping . or When you are viewing the snapshots, you can tap to play the sound. Refer to 6 Connect Bluetooth to set the Bluetooth. For more information contained in capture snapshots or videos, you can install the thermography client to analyse them.
User Manual of Handheld Thermography Camera 6 Connect Bluetooth Purpose: After pairing the device with bluetooth headsets successfully, you can record and hear the sound contained in the videos or images via bluetooth headsets Steps: 1. Select Local Settings ( 2. 3. Go to Local Settings > Device Settings > Bluetooth. Bluetooth to enable the bluetooth function. The Tap device will search the nearby enabled bluetooth headsets and pair them automatically. You can also press ) from the main menu.
User Manual of Handheld Thermography Camera 4. 5. Tap Close to hide the keypad. Tap OK. Search the “HIKMICRO Viewer” on App Store (iOS System) or Google Play TM (Android System) Launch the app and follow the startup wizard to create, and register an account. 7. Add the device to online devices. Result: You can view the live view, capture snapshots, and record videos via the client. 6. This function varies according to different camera models. 7.
User Manual of Handheld Thermography Camera 6. 7. Connect your phone to the WLAN Hot Spot of the device. Search the “HIKMICRO Viewer” on App Store (iOS System) or Google Play TM (Android System). 8. Launch the app and follow the startup wizard to create, and register an account. 9. Select Wi-Fi configuration in the software, enter the serial number of device to add the device.
User Manual of Handheld Thermography Camera 3. Disconnect the device from your PC. 4. Reboot the device and then it will upgrade automatically. The upgrading process will be displayed in the main interface. After the upgrading, the device automatically reboots. You can view the current version in Local Settings ( )> Device Information. 8.3 Restore Device Go to Local Settings ( ) > Device Settings > Device Initialize to initialize the device and restore default settings. 9 Appendix 9.
User Manual of Handheld Thermography Camera Water 9.2 0.96 Device Command Scan the following QR code to get device common serial port commands. Note that the command list contains the commonly used serial port commands for Hikvision thermal cameras. 9.3 Device Communication Matrix Scan the following QR code to get device communication matrix. Note that the matrix contains all communication ports of Hikvision thermal cameras.
User Manual of Handheld Thermography Camera 9.4 Frequently Asked Questions (FAQ) Q: A: Q: A: Q: A: Q: A: Q: A: Why is the charge indicator flashing red? Examine the items below. 1. Examine whether the device is charged with the standard power adapter. 2. Plug and unplug the battery once. 3. Make sure the charging temperature is above 0 °C (32 °F). Device image is fuzzy. How to adjust it? Refer to Focus Lens to adjust the focus knob clockwise or anticlockwise.
UD19243B 0504142000413