Thermographic Handheld Camera User Manual
User Manual of Thermographic Handheld Camera © 2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons.
User Manual of Thermographic Handheld Camera YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS.
User Manual of Thermographic Handheld Camera This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2.
User Manual of Thermographic Handheld Camera Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
User Manual of Thermographic Handheld Camera These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. Laws and Regulations ● Use of the product must be in strict compliance with the local electrical safety regulations. Transportation and Storage ● Keep the device in original or similar packaging while transporting it. ● Keep all wrappers after unpacking them for future use.
User Manual of Thermographic Handheld Camera necessary. ● If the product does not work properly, please contact your dealer or the nearest service center. We shall not assume any responsibility for problems caused by unauthorized repair or maintenance. ● A few device components (e.g., electrolytic capacitor) require regular replacement. The average lifespan varies, so periodic checking is recommended. Contact your dealer for details.
User Manual of Thermographic Handheld Camera viii
User Manual of Thermographic Handheld Camera Table of Contents 1 Overview .............................................................................................. 1 1.1 1.2 1.3 2 Device Description ..................................................................................... 1 Main Functions ......................................................................................... 1 Appearance ...............................................................................................
User Manual of Thermographic Handheld Camera 7 Hik-Thermal APP Connection ............................................................... 26 7.1 7.2 8 Maintenance....................................................................................... 28 8.1 8.2 8.3 9 Connect via Wi-Fi .................................................................................... 26 Connect via Hot Spot................................................................................ 27 View Device Information .....
User Manual of Thermographic Handheld Camera 1 Overview 1.1 Device Description The thermographic handheld camera is a device with both optical images and thermal images. It can realize thermography, video recording, snapshot capturing, alarm. It can connect to Wi-Fi, hotspot, and Bluetooth. The built-in high-sensitivity IR detector and high-performance sensor detect the variation of temperature and measure the real-time temperature.
User Manual of Thermographic Handheld Camera Device supports multiple palettes, and you can set the palette mode according to the alarm function. Client Software Connection You can connect the device with Hik-Thermal APP via Wi-Fi or hot spot to view live view, capture, and recording, etc. on your phone. You can connect the device with iVMS-4800 to analyze the thermography pictures captured by devices.
User Manual of Thermographic Handheld Camera 1.3 Appearance Audio LED Indicator Loudspeaker Touch Screen Lens Sheet ON/OFF Laser (Reserved) Back Navigation Focus Knob Lens Cover Thermal Lens Tripod Interface Trigger LED Light (Reserved) Laser (Reserved) Optical Lens Battery Component Laser Button Navigation Button Lens Sheet Button Back Button Focus Knob Cable Interface SD Card Slot Function Reserved. Menu Button: Press ▽, △, ▷, and ◁ to select parameters. Press OK to confirm.
User Manual of Thermographic Handheld Camera Component Trigger Cable Interface Function Pulls the trigger to record videos or capture snapshots. Connects the device to your PC via cable to export files. 2 Preparation 2.1 Charge Device 2.1.1 Charge Device via Cable Interface Before you start: Please make sure the battery is installed before charging. Steps: 1. Open the top cover of the device. 2. Connect the interface and the power adaptor with Type-C cable. Type-C Interface 2.1.
User Manual of Thermographic Handheld Camera Battery Steps: 1. Hold the device, and press both battery lock catches of the device. See figure below. Battery Lock Catch Handheld Camera Battery Base 2. Hold the lock catches, and draw the battery base to take out the battery. See figure below.
User Manual of Thermographic Handheld Camera 3. Insert the battery into the charging base. See figure below. You can see the charging status via the pilot lamp on the charging base. Battery Charging Base Front View Side View 4. When the battery is fully charged, draw the battery from the charging base. 5. Align the ribbed piece on battery with the notch of the device, and insert battery into the device. See figure below.
User Manual of Thermographic Handheld Camera 2.2 Power On/Off Power On Remove the lens cover, and hold the button for over three seconds to turn on the device. You can observe the target when the interface of the device is stable. It may take at least 30 s until the device is ready for using when you power on it. Power Off When the monocular is turned on, hold the seconds to power off the device. button for three 2.2.
User Manual of Thermographic Handheld Camera Button control Press the navigation buttons to configure the device. 2.4 - Press the △, ▽, ▷, and ◁ to move the cursor up/down/right/left. - Press OK to confirm. Menu Description In the observation interface, tap the screen or press OK to show the menu bar. See figure below.
User Manual of Thermographic Handheld Camera Real- time Temperature Temperature Scale Menu Icons Min. Temperature Display Center Temperature Display Max. Temperature Display Status Icons 3 Display Settings 3.1 Focus Lens Before you start: Adjust the lens focal length properly before any other configuration, or it may affect the image display and temperature accuracy. Steps: 1. Power on the device. 2. Aim the device lens to the appropriate scene.
User Manual of Thermographic Handheld Camera 3. Adjust the focus knob clockwise or anticlockwise. See figure below. FAR NEAR DO NOT touch the lens to avoid affecting the display effect. 3.2 Set Screen Brightness Go to Local Settings ( ) > Device Settings > Display Brightness to set the screen brightness. It can be set as Low, Medium, or High. 3.3 Set Display Mode Purpose: You can set the thermal/optical view of the device. Thermal, Fusion, PIP, and Optical are selectable. Steps: 1.
User Manual of Thermographic Handheld Camera 2. Tap the icons to select a view mode. Icon 3. 3.4 Press Mode Description Thermal In thermal mode, the device displays the thermal view. Fusion In fusion mode, the device displays the combined view of thermal channel and optical channel. You can tap in live view and press ▷ and ◁ to adjust fusion level. Or you can adjust it in Settings > Image Settings > Fusion Level.
User Manual of Thermographic Handheld Camera 2. Tap the icons to select a palette type. Icon 3. 3.5 Press Palette Description White Hot The hot part is light-colored in view. Black Hot The hot part is black-colored in view. Rainbow The target displays multiple colors. It’s suitable for scene without obvious temperature difference. Ironbow The target is colored as heated iron. Red Hot The hot part is red-colored in view.
User Manual of Thermographic Handheld Camera 3.7 Display Date and Time Go to Local Settings ( ) > Image Settings > Display Settings to enable the date and time display. Then you can view the date and time information in live view interface. 4 Temperature Measurement Purpose: The thermography (temperature measurement) function provides the real-time temperature of the scene and displays it on the left of your screen. The thermography function is turned on by default. 4.
User Manual of Thermographic Handheld Camera Thermography Range Select the thermography range. The device can detect the temperature and switch thermography range automatically in Auto Switch mode. Emissivity Set the emissivity of your target as the effectiveness in emitting energy as thermal radiation. Refer to the 9.1 Common Material Emissivity Reference for Emissivity values. Go to Local Settings ( ) > Image Settings > Display Settings to enable/disable the emissivity display.
User Manual of Thermographic Handheld Camera Use this function to improve temperature measurement accuracy. 3. Return to previous menu to save the settings. 4.1.1 Set Units Go to Local Settings > Device Settings > Unit Settings to set the temperature unit and distance unit. You can go to Local Settings > Image Settings > Display Settings to enable/disable the temperature unit display. 4.
User Manual of Thermographic Handheld Camera Manual Adjustment: 1) Select Manual ( 2) Press OK to confirm. The color-temperature bar ). displays. 3) Press ▷ to enlarge the temperature section range (e.g. temperature range changes from 20 °C - 40 °C to 19 °C - 41 °C), or press ◁ to narrow the temperature range. 4) Press △ to move the temperature section higher (e.g. temperature range changes from 20 °C - 40 °C to 30 °C - 50 °C), or press ▽ to lower the temperature section. 3. 4.3 Press to exit.
User Manual of Thermographic Handheld Camera 4.3.1 Set Point Rule You can set Center Point Thermography, High-Temperature Point, Low-Temperature Point, and Custom Point Thermography. Center Point Thermography System detects the temperature of the center. Tap and the temperature (center of view) displays Cen: XX. High-Temperature Point System locates the point of the highest temperature. Tap and the temperature (Highest temperature of view) displays Max: XX.
User Manual of Thermographic Handheld Camera 1. Choose on the interface. 2. Press OK to generate a default line. 3. Press the △, ▽, ▷, and ◁ to move the line up/down/left/right. 4. Drag points of the line on the touch-screen to extend or shorten the line. 5. Press OK. The Max. Temperature, Low Temperature, and Average Temperature of line (e.g. L1) displays L1 Max: XX Min: XX Avg: XX. The real-time temperature trend chart will display. Only one line supported. 4.3.3 Set Frame Rule Steps: 1.
User Manual of Thermographic Handheld Camera 4.3.4 Delete Rules Tap and press OK to clear all temperature rules. Or tap and choose the single rule you want to delete to delete it. 4.4 Set Black Body Temperature Calibration You need to purchase black body according to your need. Skip this step if the device is not equipped with black body. If black body is installed around the device, setting the black body temperature calibration can improve the temperature measurement accuracy.
User Manual of Thermographic Handheld Camera 2. Press the △ and ▽ or tap the screen to aim the calibration point at the black body. 3. Press OK to complete calibration. 4.4.2 Manual Calibration Steps: 1. Press the △ and ▽ to select Manual and press OK to start manual calibration. 2. Aim the device at the black body and press OK to complete calibration.
User Manual of Thermographic Handheld Camera 4.5 Set Temperature Alarm Before you start: Go to Palettes Settings ( ) to set the palette. Purpose: Set the alarm rules and the device will alarm when the temperature triggers the rule. Steps: 1. Go to Palettes Settings ( 2. Tap on the icons to select an alarm rule type. 3. (Optional) Press the △ and ▽ to select between upper limit and lower limit. 4. Press the ◁ and ▷ to adjust the rule temperature. Icon ) from the main menu.
User Manual of Thermographic Handheld Camera device alarms. Insulation Alarm 5. Press Set the alarm temperature section (e.g., 90 °C to 120 °C), when target temperature is without the section (e.g., 70 °C or 125 °C), the device alarms. to exit. Go to Local Settings > Image Settings >Audible Warning. Tap on to enable audible warning. The device will sound when alarm is triggered.
User Manual of Thermographic Handheld Camera 5. 6. Press to exit. In the live view interface, pull the trigger to capture snapshot. 7. The live view freezes and device displays the snapshot editing interface. 1) Set text remark or voice remark. - Tap to add text remarks. Tap the screen to show the keypad interface, enter the comment and confirm. - Tap to add voice remarks. Hold OK to start recording and release the button to stop recording. 2) Add thermography data.
User Manual of Thermographic Handheld Camera 5.2 Record Video Steps: 1. Select Local Settings ( 2. Go to Local Settings > Camera Settings > Trigger Settings. ) from the main menu. 3. Select Record. 4. Press OK. You can set the Flashlight Setting ON/OFF if required. 5. 6. Press to exit. In the live view interface, pull the trigger to start recording. The recording icon and count down number display in the interface. 7. When you finish, pull the trigger again to stop recording.
User Manual of Thermographic Handheld Camera 2. Press the △, ▽, ▷, and ◁ to select the video or snapshot. 3. Press OK to view the file. 5.4 When you are viewing the videos or capturing snapshots, you can switch the file by tapping . or When you are viewing the snapshots, you can tap to play the sound. Refer to 6 Connect Bluetooth to set the Bluetooth. For more information contained in capture snapshots or videos, you can install the thermography client to analyse them.
User Manual of Thermographic Handheld Camera 6 Connect Bluetooth Purpose: After pairing the device with bluetooth headsets successfully, you can record and hear the sound contained in the videos or images via bluetooth headsets Steps: 1. Select Local Settings ( 2. 3. Go to Local Settings > Device Settings > Bluetooth. Tap Bluetooth to enable the bluetooth function. The device will search the nearby enabled bluetooth headsets and pair them automatically. You can also press ) from the main menu.
User Manual of Thermographic Handheld Camera 6. Launch the app and follow the startup wizard to create, and register an account. 7. Add the device to online devices. Result: You can view the live view, capture snapshots, and record videos via the client. 7.2 Connect via Hot Spot Before you start: Download and install client software on your phone. Steps: 1. Go to Local Settings > Device Settings > Wi-Fi Hotspot Settings. 2. Tap on Hot Spot to enable the WLAN hot spot function. 3.
User Manual of Thermographic Handheld Camera 6. 7. Connect your phone to the WLAN Hot Spot of the device. Launch the app and follow the startup wizard to create, and register an account. 8. Select Wi-Fi configuration in the software, enter the serial number of device to add the device. Refer to the manual of client software for details Result: You can view the live view, capture snapshots, and record videos via the client. 8 Maintenance 8.
User Manual of Thermographic Handheld Camera 4. Reboot the device and then it will upgrade automatically. The upgrading process will be displayed in the main interface. After the upgrading, the device automatically reboots. You can view the current version in Local Settings ( )> Device Information. 8.3 Restore Device Go to Local Settings ( ) > Device Settings > Device Initialize to initialize the device and restore default settings. 9 Appendix 9.
User Manual of Thermographic Handheld Camera 9.2 Device Command Scan the following QR code to get device common serial port commands. Note that the command list contains the commonly used serial port commands for Hikvision thermal cameras. 9.3 Device Communication Matrix Scan the following QR code to get device communication matrix. Note that the matrix contains all communication ports of Hikvision thermal cameras.
User Manual of Thermographic Handheld Camera 9.4 Frequently Asked Questions (FAQ) Q: A: Q: A: Q: A: Q: A: Q: A: Why is the charge indicator flashing red? Examine the items below. 1. Examine whether the device is charged with the standard power adapter. 2. Plug and unplug the battery once. 3. Make sure the charging temperature is above 0 °C (32 °F). Device image is fuzzy. How to adjust it? Refer to Focus Lens to adjust the focus knob clockwise or anticlockwise.
UD18523B 0504042000306