5. Set the left/right/up/down limits with the PTZ control panel, and click to confirm settings.
6. Optional: Click Clear to delete the saved scan area.
7. Click Save.
8. Click Call Linear Scan to start linear scan, and click Stop Linear Scan to stop linear scan.
When setting the linear scan area, make sure the target area is both included in the optical
channel and the thermal channel.
8.6 Set Limit
The device can move only within the limited range.
Steps
1. Go to Configuration PTZ Limit.
2. Select Limit Type.
Manual Stops: The movement range limit when you control the device manually.
Scan Stops: The movement range limit when the device scans automatically.
Scan limit is supported only by devices that have a scan function.
3. Click Set and set limits according to the prompt on the live image.
4. Optional: Click Clear to clear the limit settings of the selected mode.
5. Click Save.
6. Check Enable Limit.
If you need to cancel all the set patrol paths, go to Configuration PTZ Clear Config, select
Clear All PTZ Limited, and click Save.
Result: The device can move within the set region only after saving the settings.
8.7 Set Initial Position
Initial position refers to the relative initial position of the device azimuth. You can set the initial position if
you need to select one point in the scene as the base point.
Steps
1. Go to Configuration PTZ Initial Position.
2. Move the device to the needed position by manually controlling the PTZ control buttons.
3. Click Set to save the information of initial position.