6.4 Set Exception Alarm
Exception such as network disconnection can trigger the device to take corresponding action.
Steps
1. Go to Configuration Event Basic Event Exception.
2. Select Exception Type.
HDD Full: The HDD storage is full.
HDD Error: Error occured in HDD.
Network Disconnected: The device is offline.
IP Address Conflicted: The IP address of current device is same as that of another device in the
network.
Illegal Login: Incorrect user name or password entered.
Voltage Instable: The power supply voltage is fluctuating.
3. Refer to Linkage Method Settings for setting linkage method.
4. Click Save.
6.5 Set Burning-Prevention
This function is used to close the shutter to prevent the lens from high temperature damage.
Steps
1. Go to Configuration Event Basic Event Burning-Prevention.
2. Check Enable.
3. Select burning-prevention mode.
Lens Movement: The lens moves automatically to avoid high temperature damage.
4. Set the protection duration.
5. Click Save.
6.6 Detect Audio Exception
Audio Exception detection detects abnormal sound in the surveillance scene such as the sudden
increase/decrease of sound intensity, and certain actions can be taken in response.
Steps
1. Go to Configuration Event Smart Event Audio Exception Detection.