4. Optional: Shield certain areas from being detected in fire source detection.
1) Go to Configuration Event Smart Event Fire Source Detection Shield.
2) Check Enable Fire Source Detection Shield.
3) Click the PTZ control buttons to find the area you want to shield from the fire detection.
4) Click Draw Area and drag the mouse in the live view window to draw the area. Release the mouse to
finish drawing.
5) You can drag the corners of the red rectangle area to change its shape and size, or drag the
rectangle to position on demand.
6) Click Clear All to clear all of the areas you set without saving them.
7) Set the value of Active Zoom Ratio on your demand, and then the shield will appear only when the
zoom ratio is greater than the predefined value
8) Click Add to save the fire detection shield, and it will be listed in the Fire Source Detection Shield List
area; you can select a region and click Delete to delete it from the list. You can also define the
color of the regions.
5. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting
linkage method.