Configure the temperature measurement rule and click any point in live view to monitor the temperature.
Steps
1. Click in the live view, and a cross cursor shows on the interface.
2. Drag the cross cursor to desired position.
3. Go to the Live View interface to view the temperature and rule of the point in the thermal channel.
3.3.6 Line Thermography
Configure the temperature measurement rule and monitor the maximum temperature of the line.
Steps
1. Click and drag the mouse to draw a line in the live view interface.
2. Click and move the line to adjust the position.
3. Click and drag the ends of the line to adjust the length.
4. Go to Live View interface to view the maximum temperature and rule of the line in the thermal channel.
3.3.7 Area Thermography
Configure the temperature measurement rule and monitor the maximum temperature of the area.
Steps
1. Click and drag the mouse in live view to draw the area and right click to finish drawing.
2. Click and move the area to adjust the position.
3. Drag the corners of the area to adjust the size and shape.
4. Go to Live View to view the maximum temperature and rule of the area in the thermal channel.
3.4 Manual Thermography
After enable the manual thermography function of the device, you can click any position on the interface
to show the real temperature.
Before You Start
Go to Configuration System Maintenance VCA Resource Type, and select Temperature Measurement
+ Behavior analysis.
Steps
1. Go to Configuration Local and set Display Temperature Info. to Yes.
2. Go to Configuration Temperature Measurement Basic Settings.
3. Check Enable Temperature Measurement.