4) Manual Calibration
Purpose:
The performance of this body thermography scheme offered by HIKVISION would be
affected by different actual working environments, and the affect factors in most
stable environments could be regarded as a kind of system error. If needed, it is
suggested to make a compensation through the manual calibration, the steps are as
following.
Steps:
1. Device start-up; wait a period of time (more than 60 minutes) for preheating.
2. For 5 to 10 individuals, complete the following 3 steps one by one:
Use the ear thermometer or other specialized thermometer to get the real
body temperature, and record.
Use the thermographic camera to get the body temperature of the same
individual, and record.
Subtract these two numbers, and record the difference value.
3. Set Manual Calibration with the average value of these difference values in Body
Temperature Compensation.
For example:
If data recorded during the calibration process are as the following table,
Real Body
Temperature/
Measured
Temperature/
Difference
Value/
Average Value
(Manual Calibration)/
36.8
36.3
0.5
0.5
37.0
36.5
0.5
36.8
36.2
0.6
36.9
36.4
0.5
37.2
36.8
0.4
thereby setting the Manual Calibration as 0.5 degrees Celsius.
4. Other Notes for Use
Before the device is used in actual body temperature measurement, it should run
for more than 60 minutes for preheating.
This product is used for preliminary screening of people with Temperature. After
alarm happens, specialized medical thermometer should be used in further body