9. Configure the following settings:
Black Body Parameters: If a blackbody is used for best performance of real-time
body temperature measurement correction, the following settings should be
configured.
Enable Blackbody Correction: Check this box if a blackbody is used for
temperature correction.
Distance: The actual distance between the camera and the blackbody.
Set Temperature and Emissivity with the actual parameters of the used
blackbody.
Draw Area: Put the correction point on the center of the blackbody. The
blackbody should be placed outside the human face detection area (blue
box in thermal channel, yellow box in optical channel) and inside the
imaging range of thermal camera (red box in optical channel).
Body Temperature Compensation: Compensate the measured value according
to the real-time environment temperature.
Enable: Check this box to enable body temperature compensation
Compensation Type: Setting as Auto is suggested; in this way, auto
compensation and manual calibration value would both added to the
measured value.
Manual Calibration: The set value would be added to the measured value.
(If this value is set as 2 degrees Celsius and the measured value is 35 degrees
Celsius, the displayed value would be 37 degrees Celsius). See Manual
Calibration part in below for details.
Environment Temperature: Setting as Auto is suggested; in this way, the
environment temperature would be automatically measured.
10. Click Save.