How to Guide
© Hangzhou Hikvision Digital Technology Co.,Ltd. All Rights Reserved. 
No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China • Tel: +86-571-8807-5998 • Fax: +1 909-595-0788 
E-Mail: support@hikvision.com • www.hikvision.com   
How to Configure Temperature Screening   
Thermographic Camera with Blackbody 
1.  General Parameters 
  Temperature Measurement Range 
30.0-45.0 Degrees Celsius 
  Temperature Measurement Accuracy 
± 0.3 Degrees Celsius 
  Camera Resolution and Focal Length 
DS-2TD1217B-3/PA: Thermal: 160 × 120, Optical: 2688 × 1520, 3mm 
DS-2TD1217B-6/PA: Thermal: 160 × 120, Optical: 2688 × 1520, 6mm 
DS-2TD2617B-6/PA: Thermal: 160 × 120, Optical: 2688 × 1520, 6mm 
DS-2TD2637B-10/P: Thermal: 384 × 288, Optical: 2688 × 1520, 10mm 
DS-2TD2636B-15/P: Thermal: 384 × 288, Optical: 2688 × 1520, 15mm 
  AI Face Detection 
Multiple targets skin-surface temperature detection at the same time (wearing 
masks or not would not affect this detection) 
  Operating Environment 
Indoor environment with calm air condition; 10-35 Degrees Celsius 
2.  Installation 
1)  Installation Cautions 
The  performance  of  this  Temperature-screening  scheme  is  greatly  affected  by 
environment. This scheme would apply only to those indoor environments, or the 
scenarios with calm air and consistent temperature. Besides, the relative installation 
location of devices and the ambient light (too bright or too dark) greatly affect the 
accuracy of  face detection.  In order to  improve measurement accuracy and  reach 
better  performance  of  human  face  detection,  the  installation  environment  has  to 
meet certain requirements: 
1.  Select installation environments with one-direction path to ensure that cameras 
capture the full faces of all passing persons. 
2.  Select installation environments with stable and sufficient lighting conditions. 
Supplementary light is required under backlight or insufficient lighting conditions 