User Manual
Table Of Contents
- Chapter 1 System Requirement
 - Chapter 2 Network Connection
 - Chapter 3 Access to the Network Camera
 - Chapter 4 Live View
 - Chapter 5 Network Camera Configuration
 - Chapter 6 Network Settings
 - Chapter 7 Video/Audio Settings
 - Chapter 8 Image Settings
 - Chapter 9 Event Settings
 - Chapter 10 Storage Settings
 - Chapter 11 Playback
 - Chapter 12 Picture
 - Appendix
 
Thermal Network Bullet Camera User Manual 
99 
Figure 9-19 Basic Settings 
2.  Check the checkboxes of the interface to set the temperature measurement 
configurations. 
  Enable Temperature Measurement: Check the checkbox to enable 
temperature measurement function.   
  Enable Color-Temperature: Check the checkbox to display temperature 
pallet in live view. 
  Display Temperature Info. on Stream: Check the checkbox to display 
temperature information in live view. 
  Add Original Data on Capture: Check the checkbox to add original data 
on capture.   
  Add Original Data on Stream: Check the checkbox to add original data 
on stream. 
  Data Refresh Interval: Select the data refresh interval from 1s to 5s. 
  Unit: Display temperature with Degree Celsius (°C)/ Degree Fahrenheit 
(°F)/ Degree Kelvin (K). 
  Temperature Range: Set the temperature range. 
  Emissivity: Set the emissivity of your target. Note: The emissivity of each 
object is different. 
  Algorithm Version: View the version of current algorithm. 
  Distance (m): The straight-line distance between the target and the 
device. 
3.  Click Save to save the settings. 
9.4.2  Advanced Settings 
Purpose: 
This function is used for measuring the temperature of detected spot and the device 
compares temperature of selected regions and alarms. 
Steps: 
1.  Enter Configuration > Temperature Measurement > Advanced Settings.   
2.  Select the temperature measurement and alarm configuration as Normal or 