Thermal Network Bullet Camera User Manual
101
Figure 9-21 Temperature Measurement Configuration
1) Set the alarm rule: Select a temperature measurement rule from the rule list and
configure the parameters.
Name: You can customize the rule name.
Type: Select Point, Line, or Frame as rule type.
Emissivity: Set the emissivity of your target. The emissivity of each object is different,
you can refer to the Quick Start Guide Appendix for details.
Distance (m): The straight-line distance between the target and the device.
Reflective Temperature: If there is any target with high emissivity in the scene,
check the checkbox and set the reflective temperature to correct the temperature. If no
such target exists, uncheck the checkbox.