User Manual
Table Of Contents
- Chapter 1 System Requirement
- Chapter 2 Network Connection
- Chapter 3 Access to the Network Camera
- Chapter 4 Live View
- Chapter 5 Network Camera Configuration
- Chapter 6 Network Settings
- Chapter 7 Video/Audio Settings
- Chapter 8 Image Settings
- Chapter 9 Event Settings
- Chapter 10 Storage Settings
- Chapter 11 Playback
- Chapter 12 Picture
- Appendix
Thermal Network Bullet Camera User Manual
99
Figure 9-19 Basic Settings
2. Check the checkboxes of the interface to set the temperature measurement
configurations.
Enable Temperature Measurement: Check the checkbox to enable
temperature measurement function.
Enable Color-Temperature: Check the checkbox to display temperature
pallet in live view.
Display Temperature Info. on Stream: Check the checkbox to display
temperature information in live view.
Add Original Data on Capture: Check the checkbox to add original data
on capture.
Add Original Data on Stream: Check the checkbox to add original data
on stream.
Data Refresh Interval: Select the data refresh interval from 1s to 5s.
Unit: Display temperature with Degree Celsius (°C)/ Degree Fahrenheit
(°F)/ Degree Kelvin (K).
Temperature Range: Set the temperature range.
Emissivity: Set the emissivity of your target. Note: The emissivity of each
object is different.
Algorithm Version: View the version of current algorithm.
Distance (m): The straight-line distance between the target and the
device.
3. Click Save to save the settings.
9.4.2 Advanced Settings
Purpose:
This function is used for measuring the temperature of detected spot and the device
compares temperature of selected regions and alarms.
Steps:
1. Enter Configuration > Temperature Measurement > Advanced Settings.
2. Select the temperature measurement and alarm configuration as Normal or