77 
4.  Move the mouse to the end of each day, a copy dialogue box pops up, and you 
can copy the current settings to other days.   
5.  Click Save to save the settings.   
Note: The time of each period can’t be overlapped. Up to 8 periods can be configured 
for each day. 
Task 3: Set the Linkage Method for Motion Detection 
Check  the  checkbox  to  select  the  linkage  method.  Audible  Warning,  Send  Email, 
Notify Surveillance Center, Upload to FTP/Memory Card/NAS, Trigger Channel and 
Trigger Alarm Output are selectable. You  can specify the linkage method when an 
event occurs.   
Figure 9-4 Linkage Method 
Note: The linkage methods vary according to the different camera models. 
  Audible Warning 
Trigger the  audible  warning  locally.  And  it only  supported  by  the device  that 
have the audio output. 
  Notify Surveillance Center 
Send an exception or alarm signal to remote management software when an event 
occurs. 
  Send Email 
Send an email with alarm information to a user or users when an event occurs. 
Note: To send the Email when an event occurs, please refer to 6.2.3to complete 