User Manual

Table Of Contents
Thermal Network Bullet Camera User Manual
97
Pixel: Click Minimum Size to draw the rectangle of the min. size on the live view.
And click Maximum Size to draw the rectangle of the max. size on the live view.
The target is smaller than the min. size or larger than the max. size will be
filtered.
Notes:
The drawn area will be converted to the pixel by the background
algorithm.
The global size filter cannot be configured if the live view is stopped.
The length of the maximum size should be longer than the length of the
minimum size, and so does the width.
4. Click Save to save the settings.
9.4 Temperature Measurement
9.4.1 Basic Settings
Purpose:
The device can measure the actual temperature of the spot being monitored. The
device alarms when temperature exceeds the temperature threshold value.
Note: Before you use the temperature measurement function, enter Configuration >
System > Maintenance > VCA Resource Type to select Temperature
Measurement + Behavior Analysis as VCA Resource Type.
Steps:
1. Enter Configuration > Temperature Measurement > Basic Settings.