User Manual
Table Of Contents
- Chapter 1 System Requirement
- Chapter 2 Network Connection
- Chapter 3 Access to the Network Camera
- Chapter 4 Live View
- Chapter 5 Network Camera Configuration
- 5.1 Configuring Local Parameters
- 5.2 Configuring Time Settings
- 5.3 Configuring Network Settings
- 5.3.1 Configuring TCP/IP Settings
- 5.3.2 Configuring Port Settings
- 5.3.3 Configuring PPPoE Settings
- 5.3.4 Configuring DDNS Settings
- 5.3.5 Configuring SNMP Settings
- 5.3.6 Configuring 802.1X Settings
- 5.3.7 Configuring QoS Settings
- 5.3.8 Configuring UPnP™ Settings
- 5.3.9 Email Sending Triggered by Alarm
- 5.3.10 Configuring NAT (Network Address Translation) Settings
- 5.3.11 Configuring FTP Settings
- 5.3.12 HTTPS Settings
- 5.4 Configuring Video and Audio Settings
- 5.5 Configuring Image Parameters
- 5.6 Configuring and Handling Alarm Events
- 5.7 Temperature Measurement
- 5.8 VCA Configuration
- Chapter 6 Storage Settings
- Chapter 7 Playback
- Chapter 8 Log Searching
- Chapter 9 Others
- Appendix
Thermometric Network Bullet Camera User Manual
75
Figure 5-46 Configuring Dynamic Fire Source Detection
3. Check the checkbox of Display Fire Source Frame on Stream to display a red
frame around the fire source on stream when fire occurs. (Optional)
4. You can slide the cursor to adjust the sensitivity degree of dynamic fire source
detection from 1to 10. The bigger the number is, the more sensitive the detecting
would be.
5. Check the checkbox to select the linkage method taken for the alarm input. Please
refer to Task 3: Set the Alarm Actions for Motion Detection in Section Motion
Detection. In the field of Other Linkage, you can check the checkbox to enable
the alarm output (The alarm output number varies depending on device ability).
6. Click Save to save the settings.
5.7 Temperature Measurement
Purpose:
When you enable this function, it measures the actual temperature of the spot being
monitored. The device alarms when temperature exceeds the temperature threshold
value.
Before You Start:
Enter Configuration > Advanced Configuration > System > VCA Resource Type
to select Temperature Measurement + Behavior Analysis as VCA Resource Type.