User Manual

Table Of Contents
Thermal Network Bullet Camera User Manual
138
b) Select the areas.
Figure 9-26 Area Temperature Comparison Alarm
c) Select the comparison rule.
d) Set the temperature difference threshold value.
Example: select Area 1 and Area 11, and set the comparison rule as
Above (Max. Temperature), and set the temperature difference
threshold to 5 °C. The device alarms when the difference of two
areas' maximum temperature is above 5 ° C.
9.4.3 Linkage Method
Purpose:
Set the linkage method of the alarm.
Steps:
1. Enter Configuration > Temperature Measurement > Linkage Method.
2. Set the arming schedule and linkage method.
Arming Schedule: Click on the time bar and drag the mouse to select