User Manual

Table Of Contents
Thermal Network Bullet Camera User Manual
134
(For Expert Mode)
1. Enter Configuration > Temperature Measurement > Advanced Settings.
2. Select the configuration mode as Expert.
3. Configure the parameters.
Name: You can customize the rule name.
Type: Select Point, Line, or Area as rule type.
Emissivity: Set the emissivity of your target. The emissivity of each
object is different, you can refer to the Appendix for details.
Distance (m): The straight-line distance between the target and the
device.
Reflective Temperature: If there is any object reflecting to the target, e.g.,
a mirror, enter the background temperature value/the reflecting object's
temperature value. If not, uncheck the checkbox.
Tolerance Temperature: The triggered alarm does NOT stop until the
temperature/temperature difference is lower/higher than rule
temperature by tolerance temperature.
Example: set tolerance temperature as C, set alarm temperature as
55°C. It alarms when its temperature reaches 55°C and only when the
temperature is below 52°C will the alarm be cancelled.