Add Original Data on Capture: Check the checkbox to add original
data on capture.
Add Original Data on Stream: Check the checkbox to add original
data on stream.
Data Refresh Interval: Select the data refresh interval from 1s to 5s.
Unit: Display temperature with Degree Celsius (°C)/ Degree
Fahrenheit (° F)/ Degree Kelvin (K).
Temperature Range: Set the temperature range.
Emissivity: Set the emissivity of your target. Note: The emissivity of
each object is different.
Algorithm Version: View the version of current algorithm.
Distance (m): The straight-line distance between the target and the
device.
3. Click Save to save the settings.
9.4.2 Configuring Temperature Measurement Rule
Before you start:
The temperature measurement function is usually used together with alarm
function. You can set the alarm linkage so that any alarm/pre-alarms can
trigger the connected alarm. You can double click current screen to show full
of it, and double click again to exit full screen.