target is more accurate and the target is generated slower.
Single Alarm: If single alarm is selected, the target in the configured area will
trigger the alarm for only once. If it is not checked, the same target will cause
the continuous alarm in the same configured area.
Scene Mode:
General: In General mode, the behavior analysis works normally.
Distant View: When the camera is installed in outdoor environment, select Distant
View mode.
Leaves Interfered View: When the camera is installed where the trees or leaves
may interfere the view, select Leaves Interfered View mode.
Restore Default: Click to restore the configured parameters to the default.
Restart VCA: Restart the algorithms library of behavior analysis.
● Global Size Filter
Note: Compared with the size filter under rule, which is aiming at each rule,
the global size filter is aim at all rules.
Steps:
1. Enter Configuration > VCA > Advanced Configuration.
2. Check the checkbox of Global Size Filter to enable the function.
3. Select the Filter Type as Actual Size or Pixel.
Actual Size: Input the length and width of both the maximum size and the
minimum size. Only the target whose size is between the minimum value
and maximum value will trigger the alarm.
Notes:
● Camera calibration has to be configured if you select the filter by