User Manual

Table Of Contents
Thermal Network Bullet Camera User Manual
127
Figure 9-20 Advanced Configuration
Detection Sensitivity [0 - 4]: Refers to the sensitivity of the camera detects a
target. The higher the value, the easier a target be recognized, and the higher
the misinformation is. The default value of 3 is recommended.
Background Update Rate [0 - 4]: It refers to the speed of the new scene
replaces the previous scene. The default value of 3 is recommended.
Minimum Target Size [0~4]: When the target size is smaller than the value, the
system’s VCA rule does not apply. The default value of 1 is recommended.
Displacement Constraint for Target Generation [0~4]: It refers to the target
generating effect. The higher is the value, the target is more accurate and the
target is generated slower.
Optical-Axis Movement: If the target moves in the camera’s optical-axis
direction, set the optical-axis movement sensitivity. The lower is the value, the