Figure 9-27 Area Temperature Comparison Alarm 
c)  Select the comparison rule. 
d)  Set the temperature difference threshold value. 
Example: select Area 1 and Area 11, and set the comparison rule as 
Above (Max. Temperature), and set the temperature difference 
threshold to 5 °C. The device alarms when the difference of two areas' 
maximum temperature is above 5 °C. 
9.4.3 Linkage Method   
Purpose:   
Set the linkage method of the alarm.   
Steps:   
1.  Enter Configuration > Temperature Measurement > Linkage Method. 
2.  Set the arming schedule and linkage method.   
  Arming  Schedule:  Click  on  the  time  bar  and  drag  the  mouse  to  select  the 
time period. 
  Linkage Method: Click Linkage Method and check the checkbox to select the 
linkage  method.  Audible  warning,  notify  surveillance  center,  send  email, 
upload to FTP,  trigger channel and  trigger alarm output  are  selectable. You 
can specify the linkage method when an event occurs.   
3.  Click Save to save the settings. 
After the settings, you can view the current temperature and humidity on the top of 