User Manual
Table Of Contents
- Chapter 1 System Requirement
 - Chapter 2 Network Connection
 - Chapter 3 Access to the Network Camera
 - Chapter 4 Live View
 - Chapter 5 Network Camera Configuration
 - Chapter 6 Network Settings
 - Chapter 7 Video/Audio Settings
 - Chapter 8 Image Settings
 - Chapter 9 Event Settings
 - Chapter 10 Storage Settings
 - Chapter 11 Playback
 - Chapter 12 Picture
 - Appendix
 
Thermal & Optical Bi-spectrum Network Bullet / Turret Camera User Manual 
115 
Figure 9-23 Temperature Measurement Configuration 
  (For Expert Mode) 
1.  Enter Configuration > Temperature Measurement > Advanced Settings.   
2.  Select the configuration mode as Expert. 
3.  Configure the parameters. 
Name: You can customize the rule name. 
Type: Select Point, Line, or Area as rule type. 
Emissivity: Set the emissivity of your target. The emissivity of each object is 
different, you can refer to the Appendix for details. 
Distance (m): The straight-line distance between the target and the device. 
Reflective Temperature: If there is any object reflecting to the target, e.g., a 
mirror,  enter  the  background  temperature  value/the  reflecting  object's 
temperature value. If not, uncheck the checkbox. 
Tolerance  Temperature:  The  triggered  alarm  does  NOT  stop  until  the 
temperature/temperature  difference  is  lower/higher  than  rule  temperature 
by tolerance temperature.   
Example: set tolerance temperature as 3°C, set alarm temperature as 55°C. It 
alarms when its temperature reaches 55°C and only when the temperature is 