User Manual

Table Of Contents
Steps
1. Go to
Conguraon → Event → Smart Event Unaended Baggage Detecon .
2. Check Enable.
3.
Oponal: Click Lock to lock PTZ control to prevent the interrupon from other PTZ related
acon during conguraon.
Normally, the PTZ control is automacally locked when you enter the conguraon interface.
You can manually resume the lock when the countdown is over.
4. Adjust the live image to the desired scene by using PTZ control
buons.
5. Draw detecon area.
1) Select a Region No.. Up to 4 regions can be set.
2) Click
Detecon Area.
3) Click on the live image to draw the boundaries of the
detecon area, and right click to
complete drawing.
6. Oponal: Set the minimum size and the maximum size for the target to improve detecon
accuracy. Only targets whose size are between the maximum size and the minimum size trigger
the detecon.
1) Click Max. Size, and drag the mouse on live image. If you want to change the size, click the
buon and draw again.
2) Click Min. Size, and drag the mouse on the live image. If you want to change the size, click
the
buon and draw again.
7. Set detecon parameters.
Sensivity
The value of the sensivity denes the size of the object which can trigger the
alarm, when the sensivity is high, a very small object can trigger the alarm.
Threshold It stands for the me of the objects le in the area. Alarm is triggered aer the
object is le and stays in the area for the set me period.
Figure 9-9 Draw Area
8. Click Save.
9. Repeat above steps to set other regions.
Network Speed Dome & Posioning System User Manual