User's Manual

Table Of Contents
Detecon
Target
You can specify the object type, and the device only detects the selected
type of objects.
8. Click Save.
9. R
epeat above steps to set other lines.
10. Set arming schedule. See Set Arming Schedule .
11. Set linkage method. See Linkage Method Sengs .
11.2.4 Set Region Entrance Detecon
Region entrance detecon is used t
o detect the object movement of entering a predened area.
When it occurs, the device takes linkage acons as response.
Steps
1. Go to Conguraon → Event → Smart Event → Region Entrance Detecon .
2. Check Enable.
3. Oponal: Click Lock to lock PTZ control to prevent the interrupon from other PTZ related
acon during conguraon.
Normally, the PTZ control is automacally locked when you enter the conguraon interface.
You c
an manually resume the lock when the countdown is over.
4. Adjust the live image to the desired scene by using PTZ control buons.
5. Draw de
tecon area.
1) Select a Region No.. Up to 4 regions can be set.
2) Click Detecon Area.
3) Click on the liv
e image to draw the boundaries of the detecon area, and right click to
complete drawing.
6. Oponal: Set the minimum size and the maximum size for the target to improve detecon
accuracy. Only targets whose size are between the maximum size and the minimum size trigger
the detecon.
1)
Click Max. Size, and drag the mouse on live image. If you want to change the size, click the
buon and draw again.
2) Click Min. Size, and drag the mouse on the live image. If you want to change the size, click
the buon and draw again.
7. Set
detecon parameters.
Sensivity It stands for the sensivity of detecng an target. The higher the value is,
the more easily the t
arget is detected.
Detecon
Target
You can specify the object type, and the device only detects the selected
type of objects.
Network Speed Dome User Manual