User's Manual
Table Of Contents
- Legal Information
- Chapter 1 Overview
- Chapter 2 Device Activation and Accessing
- Chapter 3 Person Arming
- Chapter 4 Vehicle Arming
- Chapter 5 Face Capture
- Chapter 6 Road Traffic
- Chapter 7 PTZ
- 7.1 PTZ Control
- 7.2 Set Preset
- 7.3 Set Patrol Scan
- 7.4 Set Pattern Scan
- 7.5 Set Limit
- 7.6 Set Initial Position
- 7.7 Set Scheduled Tasks
- 7.8 Set Park Action
- 7.9 Set Privacy Mask
- 7.10 Set Smart Tracking
- 7.11 Set Device Position
- 7.12 Set Power Off Memory
- 7.13 Set PTZ Priority
- 7.14 Set Rapid Focus
- 7.15 GPS Calibration
- Chapter 8 Live View
- 8.1 Live View Parameters
- 8.1.1 Start and Stop Live View
- 8.1.2 Aspect Ratio
- 8.1.3 Live View Stream Type
- 8.1.4 Quick Set Live View
- 8.1.5 Select the Third-Party Plug-in
- 8.1.6 Start Digital Zoom
- 8.1.7 Conduct Regional Focus
- 8.1.8 Conduct Regional Exposure
- 8.1.9 Count Pixel
- 8.1.10 Light
- 8.1.11 Operate Wiper
- 8.1.12 Lens Initialization
- 8.1.13 Track Manually
- 8.1.14 Conduct 3D Positioning
- 8.2 Set Transmission Parameters
- 8.3 Smart Display
- 8.1 Live View Parameters
- Chapter 9 Video and Audio
- Chapter 10 Video Recording and Picture Capture
- Chapter 11 Event and Alarm
- Chapter 12 Arming Schedule and Alarm Linkage
- Chapter 13 Network Settings
- Chapter 14 System and Security
- 14.1 View Device Information
- 14.2 Restore and Default
- 14.3 Search and Manage Log
- 14.4 Import and Export Configuration File
- 14.5 Export Diagnose Information
- 14.6 Reboot
- 14.7 Upgrade
- 14.8 View Open Source Software License
- 14.9 Set Live View Connection
- 14.10 Time and Date
- 14.11 Set RS-485
- 14.12 Security
- Appendix A. Device Command
- Appendix B. Device Communication Matrix
Tuning Mode
The mode is only for the professional users.
Tracking Capture
Check to enable the device to capture the targets during the tracking.
Some capture parameters are allowed to adjust.
Face Capture Threshold
It refers for the quality of face to trigger capture and alarm. Higher value means beer quality
should be met to trigger capture and alarm.
Human Body Capture Threshold
It refers for the quality of human body to trigger capture and alarm. Higher value means beer
quality should be met to trigger capture and alarm.
Tracking Parameters
Zooming Control
Two modes are available. Controlled by target frame or by lt angle of the device.
By Tilt Angle
The device calculates the tracking zoom rao automacally according to the lt angle of the
device.
Note
The atude of the de
vice aects the accuracy of this zooming control mode. For the model
with a built-in gyroscope, try to calibrate the atude if some zooming problems happen
during tracking. See Set Device Posion for instrucons.
By Target Frame
The track
ed target has a virtual frame around. The device calculates a suitable zoom rao
according to the frame and the set Tr
acking Zoom Rao. Larger value means bigger zoom
rao.
Dwell Time aer Failed Tracking
The me the device stays at the posion where the target tracking fails.
Report Interval of Tracking Info
The alarming informaon upload interval during tracking.
Wait t
o Stop Tracking If Low Validity
The validity is an internal parameter that helps judge whether the device should keep tracking
or not. This parameter is the waing me level before the device stops tracking when the
validity is low. Larger value means longer waing me.
Wait to Lower Tracking Speed If Low Validity
Network Speed Dome User Manual