User Manual

Table Of Contents
User Manual of E Series Network Speed Dome
© Hikvision
28
5 seconds, 10 seconds, Always Close or Always Open.
Preset Status: Set the preset name display duration while calling the preset as 2 seconds,
5 seconds, 10 seconds, Always Close or Always Open.
Power-off Memory: The dome can resume its previous PTZ status or actions after it restarted
from a power-off. You can set the time point of which the dome resumes its PTZ status. You
can set it to resume the status of 30 seconds, 60 seconds, 300 seconds or 600 seconds before
power-off.
3. Click to save the settings.
5.3 Configuring PTZ Limits
Purpose:
The dome can be programmed to move within the configurable PTZ limits (left/right, up/down).
Steps:
1. Enter the Limit Configuration interface:
Configuration > Advanced Configuration > PTZ > Limit
Figure 5-3 Configure the PTZ Limit
2. Click the checkbox of Enable Limit and choose the limit type as manual stops or scan stops.
Manual Stops:
When manual limit stops are set, you can operate the PTZ control panel manually only in the
limited surveillance area.
Scan Stops:
When scan limit stops are set, the random scan, frame scan, auto scan, tilt scan, panorama
scan is performed only in the limited surveillance area.
Manual Stops of Limit Type is prior to Scan Stops. When you set these two limit
types at the same time, Manual Stops is valid and Scan Stops is invalid.