User's Manual

Table Of Contents
2) Click Min. Size, and drag the mouse on the live image. If you want to change the size, click
the buon and draw again.
7. Set detecon parameters.
Sensivity It stands for the sensivity of detecng an target. The higher the value is,
the mor
e easily the target is detected.
Detecon
Target
You can specify the object type, and the device only detects the selected
type of objects.
Figure 8-7 Draw Area
8. Click Sa
ve.
9. Repeat above steps to set other regions.
10. Set arming schedule. See Set Arming Schedule .
11. Set linkage method. See Linkage Method Sengs .
8.2.6 Set Object Removal Detecon
Object removal
detecon detects whether the objects are removed from the predened detecon
area, such as exhibits on display. When it occurs, the device takes linkage acons as response.
Steps
1. Go to Conguraon → E
vent → Smart Event → Object Removal Detecon .
2. Check Enable.
3. Oponal: Click Lock to lock PTZ control to prevent the interrupon from other PTZ related
acon during conguraon.
Normally, the PTZ control is automacally locked when you enter the conguraon interface.
Y
ou can manually resume the lock when the countdown is over.
4. Adjust the live image to the desired scene by using PTZ control buons.
5. Dr
aw detecon area.
1) Select a Region No.. Up to 4 regions can be set.
Network Speed Dome User Manual