DS-2CD6825G0-C-IVS-User-Manul

Table Of Contents
Dual-Lens People Counting Camera User Manual
24
Notify Surveillance Center
Send an exception or alarm signal to remote management software when an event
occurs.
4.2.2 Data Uploading Setting
Select a trigger counting mode. None, or trigger by alarm input.
None: Camera keeps counting, unaffected by door status.
When you select None, people counting data is sent to surveillance center and
client software through SDK (default) and HTTP (if configured).
To upload real-time data, check the Real-Time Upload Data checkbox.
To upload data regularly, set the Data Statistics Cycle as desired.
Trigger by Alarm Input: Camera judges the door status by alarm input signals.
Counting only happens when the door status is considered as open.
1. Select Alarm Input Signal Type according to the actual signal type of the
vehicle.
Note: Alarm input should be configured. Go to Event > Basic Event > Alarm
Input. Refer to Section 10.1.2
Level Signal: If high level is door open and low level is door closed, set the
alarm type as NO. If high level is door closed and low level is door open, set
the alarm type as NC.
Pulse Signal: Set the alarm type of both alarm input No. A<-1 and alarm
input No. A<-2 as NO.
2. (Optional) If RS-485 data transmission is required, select ON.
Then you should set RS-485 parameters at System > System Settings >
RS485
3. (Optional) If data uploading by HTTP is required, set up the HTTP Data
Transmission parameters.