User Manual
Table Of Contents
- Chapter 1 System Requirement
- Chapter 2 Network Connection
- Chapter 3 Access to the Network Camera
- Chapter 4 Live View
- Chapter 5 Network Camera Configuration
- Chapter 6 Network Settings
- Chapter 7 Video/Audio Settings
- Chapter 8 Configuring Image Parameters
- Chapter 9 Configuring Event Settings- 9.1 Configuring Motion Detection
- 9.2 Configuring Video Tampering Alarm
- 9.3 Configuring Alarm Input
- 9.4 Configuring Alarm Output
- 9.5 Handling Exception
- 9.6 Configuring Audio Exception Detection
- 9.7 Configuring Intrusion Detection
- 9.8 Configuring Line Crossing Detection
- 9.9 Configuring Region Entrance Detection
- 9.10 Configuring Region Exiting Detection
- 9.11 Configuring Unattended Baggage Detection
- 9.12 Configuring Object Removal Detection
 
- Chapter 10 Storage Settings
- Chapter 11 People Counting
- Chapter 12 Heat Map
- Chapter 13 Intersection Analysis
- Chapter 14 Playback
- Chapter 15 Picture
- Chapter 16 Application
- Appendix
User Manual of Network Fisheye Camera 
100 
Min. Size: The minimum size of a valid target. Targets with smaller sizes would 
not trigger detection. 
7.  Click Stop Drawing when finish drawing. 
8.  Drag the slider to set the sensitivity value. 
Sensitivity: Range [1-100]. Sensitivity stands for the percentage of the body part 
of an acceptable target that enters the pre-defined region. 
Sensitivity = 100 – S
1
/S
T
*100 
S
1
 stands for the target body part that enters the pre-defined region S
T
 stands for 
the complete target body.   
Example:  if  you  set  the  value  as  60,  the  action  can  be  counted  as  a  region 
entrance action only when 40 percent body part enters the region. 
Note: The Sensitivity of the detection is supported by certain models. Refer to 
actual display for details. 
9.  Repeat the above steps to configure other regions. Up to 4 regions can be set. You 
can click the Clear button to clear all pre-defined regions. 
10.  Click Arming Schedule to set the arming schedule. 
11.  Click Linkage Method to select the linkage methods. 
12.  Click Save to save the settings. 
9.10 Configuring Region Exiting Detection 
Purpose: 
Region exiting detection function detects people, vehicle or other objects which exit 
from a pre-defined virtual region, and  some certain actions can be taken when  the 
alarm is triggered.   
Steps: 
1.  Enter the Region Exiting Detection settings interface, Configuration > Event > 
Smart Event > Region Exiting Detection. 










