User Manual

Table Of Contents
Steps
1. Go to
Conguraon → Event → Smart Event → Intrusion Detecon .
2. Check Enable.
3. Select a Region. For the
detecon region sengs, refer to Draw Area .
4.
Set rules.
Sensivity Sensivity stands for the percentage of the body part of an acceptable target
that enters the pre-dened region. Sensivity = 100 - S1/ST × 100. S1 stands
for the target body part that goes across the pre-dened region. ST stands
for the complete target body. The higher the value of
sensivity is, the more
easily the alarm can be triggered.
Threshold Threshold stands for the threshold for the me of the object loitering in the
region. If the me that one object stays exceeds the threshold, the alarm is
triggered. The larger the value of the threshold is, the longer the alarm
triggering
me is.
Detecon
Target
Human and vehicle are available. If the detecon target is not selected, all
the detected targets will be reported, including the human and vehicle.
Target
Validity
If you set a higher validity, the required target features should be more
obvious, and the alarm accuracy would be higher. The target with less
obvious features would be missing.
Figure 6-3 Set Rule
5. Oponal: You can set the parameters of mulple areas by repeang the above steps.
6. For the arming schedule
sengs, refer to Set Arming Schedule . For the linkage method
sengs, refer to Linkage Method Sengs .
7. Click Save.
Network Camera User Manual