User Manual
Table Of Contents
- Initiatives on the Use of Video Products
- Legal Information
- Chapter 1 Device Activation and Accessing
- Chapter 2 Network Camera Configuration
- 2.1 Update Firmware
- 2.2 Symbol Conventions
- 2.3 Safety Instruction
- 2.4 System Requirement
- 2.5 Live View
- 2.6 Video and Audio
- 2.7 Video Recording and Picture Capture
- 2.8 Event and Alarm
- 2.9 Network Settings
- 2.10 Arming Schedule and Alarm Linkage
- 2.11 System and Security
- 2.11.1 View Device Information
- 2.11.2 Search and Manage Log
- 2.11.3 Simultaneous Login
- 2.11.4 Import and Export Configuration File
- 2.11.5 Export Diagnose Information
- 2.11.6 Reboot
- 2.11.7 Restore and Default
- 2.11.8 Upgrade
- 2.11.9 Device Auto Maintenance
- 2.11.10 View Open Source Software License
- 2.11.11 Wiegand
- 2.11.12 Metadata
- 2.11.13 Time and Date
- 2.11.14 Set RS-485
- 2.11.15 Set RS-232
- 2.11.16 Power Consumption Mode
- 2.11.17 External Device
- 2.11.18 Security
- 2.11.19 Certificate Management
- 2.11.20 User and Account
- 2.12 VCA Resource
- 2.13 Smart Display
- 2.14 EPTZ
- 2.15 Image Stitching
- Appendix A. FAQ
- Appendix B. Device Command
- Appendix C. Device Communication Matrix
4.
Set the minimum size and the maximum size for the target to improve detecon accuracy. Only
targets whose size are between the maximum size and the minimum size trigger the detecon.
For the detail sengs, refer to Set Size Filter .
5.
Set rules.
Sensivity
Sensivity
stands for the percentage of the body part of an acceptable target that enters the
predened region. Sensivity = 100 - S1/ST × 100. S1 stands for the target body part that goes
across the predened region. ST stands for the complete target body. The higher the value of
sensivity is, the more easily the alarm can be triggered.
Threshold
Threshold stands for the threshold for the me of the object loitering in the region. If the
me that one object stays exceeds the threshold, the alarm is triggered. The larger the value
of the threshold is, the longer the alarm triggering
me is.
Figure 2-8 Set Rule
6.
Oponal: You can set the parameters of mulple areas by repeang the above steps.
7.
For the arming schedule
sengs, refer to Set Arming Schedule . For the linkage method sengs,
refer to Linkage Method Sengs .
8.
Click Save.
Set Line Crossing
Detecon
It is used to detect objects crossing a predened virtual line. If it occurs, the device can take linkage
acons.
Before You Start
●
Go to VCA → VCA Resource , and select Smart Event.
●
For the device
supporng HEOP, go to VCA → APP to import and enable Smart Event.
Steps
1.
Go to VCA → Smart Event → Line Crossing Detecon .
Network Camera User Manual
54