User's Manual
Table Of Contents
- Chapter 1 System Requirement
 - Chapter 2 Network Connection
 - Chapter 3 Access to the Network Camera
 - Chapter 4 Wi-Fi Settings
 - Chapter 5 Live View
 - Chapter 6 Network Camera Configuration
 - Chapter 7 Network Settings
 - Chapter 8 Video/Audio Settings
 - Chapter 9 Image Settings
 - Chapter 10 Event Settings
- 10.1 Basic Events
 - 10.2 Smart Events
- 10.2.1 Configuring Audio Exception Detection
 - 10.2.2 Configuring Defocus Detection
 - 10.2.3 Configuring Scene Change Detection
 - 10.2.4 Configuring Face Detection
 - 10.2.5 Configuring Intrusion Detection
 - 10.2.6 Configuring Line Crossing Detection
 - 10.2.7 Configuring Region Entrance Detection
 - 10.2.8 Configuring Region Exiting Detection
 - 10.2.9 Configuring Unattended Baggage Detection
 - 10.2.10 Configuring Object Removal Detection
 
 - 10.3 VCA Configuration
 
 - Chapter 11 Storage Settings
 - Chapter 12 Playback
 - Chapter 13 Picture
 - Chapter 14 Application
 - Appendix
 
Network Camera User Manual 
128 
Max. Size: The maximum size of a valid target. Targets with larger sizes would 
not trigger detection. 
Min. Size: The minimum size of a valid target. Targets with smaller sizes would 
not trigger detection. 
7.  Select the direction for line crossing detection. And you can select the directions 
as A<->B, A ->B, and B->A. 
A<->B: The object going across the plane with both directions can be detected and 
alarms are triggered.  
A->B: Only the object crossing the configured line from the A side to the B side 
can be detected.  
B->A: Only the object crossing the configured line from the B side to the A side 
can be detected. 
8.  Click Stop Drawing when finish drawing. 
9.  Drag the slider to set the sensitivity value. 
Sensitivity: Range [1-100]. It stands for the percentage of the body part of an 
acceptable target that goes across the pre-defined line. 
Sensitivity = 100 – S
1
/S
T
*100 
S
1
 stands for the target body part that goes across the pre-defined line. S
T
 stands 
for the complete target body.   
Example: if you set the value as 60, the action can be counted as a line crossing 
action only when 40 percent or more body part goes across the line.   
Note: The Sensitivity of the detection is supported by certain models. Refer to 
actual display for details. 
10.  Repeat the above steps to configure other lines. Up to 4 lines can be set. You can 
click the Clear button to clear all pre-defined lines. 
11.  Click the Arming Schedule to set the arming schedule. 
12.  Select  the  linkage  methods  for  line  crossing  detection,  including  Notify 
Surveillance  Center,  Send  Email,  Upload  to  FTP/Memory  Card/NAS,  Trigger 
Channel and Trigger Alarm Output. 
13.  Click Save to save the settings. 