User's Manual
Table Of Contents
- Chapter 1 System Requirement
- Chapter 2 Network Connection
- Chapter 3 Access to the Network Camera
- Chapter 4 Wi-Fi Settings
- Chapter 5 Live View
- Chapter 6 Network Camera Configuration
- Chapter 7 Network Settings- 7.1 Configuring Basic Settings
- 7.2 Configure Advanced Settings- 7.2.1 Configuring SNMP Settings
- 7.2.2 Configuring FTP Settings
- 7.2.3 Configuring Email Settings
- 7.2.4 Platform Access
- 7.2.5 Wireless Dial
- 7.2.6 HTTPS Settings
- 7.2.7 Configuring QoS Settings
- 7.2.8 Configuring 802.1X Settings
- 7.2.9 Integration Protocol
- 7.2.10 Bandwidth Adaptation
- 7.2.11 Network Service
- 7.2.12 Smooth Streaming
 
 
- Chapter 8 Video/Audio Settings
- Chapter 9 Image Settings
- Chapter 10 Event Settings- 10.1 Basic Events
- 10.2 Smart Events- 10.2.1 Configuring Audio Exception Detection
- 10.2.2 Configuring Defocus Detection
- 10.2.3 Configuring Scene Change Detection
- 10.2.4 Configuring Face Detection
- 10.2.5 Configuring Intrusion Detection
- 10.2.6 Configuring Line Crossing Detection
- 10.2.7 Configuring Region Entrance Detection
- 10.2.8 Configuring Region Exiting Detection
- 10.2.9 Configuring Unattended Baggage Detection
- 10.2.10 Configuring Object Removal Detection
 
- 10.3 VCA Configuration
 
- Chapter 11 Storage Settings
- Chapter 12 Playback
- Chapter 13 Picture
- Chapter 14 Application
- Appendix
Network Camera User Manual 
168 
trigger one notification. 
ii.  Set regional people queuing-up settings. 
Check  OSD  to  display  the  region  name  and  its  real-time  queuing-up 
people number. 
Alarm  Trigger  Condition:  When  the  people  number  in  the  region  is 
greater than, less than, equal to or not equal to the set threshold, an alarm 
is triggered.   
Alarm  threshold:  An  alarm  is  triggered  when  the  alarm  threshold 
condition is met. 
iii.  Set waiting time detection settings. 
Alarm  Trigger  Condition:  When  the  people  number  in  the  region  is 
greater than, less than, equal to or not equal to the set threshold, an alarm 
is triggered.   
Alarm  threshold:  An  alarm  is  triggered  when  the  alarm  threshold 
condition is met. 
c)  Repeat  above  steps  to  set  up  other  regions  if  needed.  Up  to  3  regions  are 
supported. 
2.  Arming Schedule.   
Set  the  arming  schedule  for  the  function.  In  the  armed  periods,  the  function  is 
active. Refer to Task 2 in Section 10.1.1. 
3.  Linkage Method. Set linkage method.   
For  triggered  alarm  information,  you  can  set  the  linkage  action  as  a  response to 
forward the information or trigger other actions. Refer to Task 3 in Section 10.1.1. 
4.  Advanced Configuration.   
(Optional) Check the queue management version and set the filtering parameters. 
Note: The function changes the detection range and the sensitivity of the queue 
management. Remain filter settings unchanged in general situations. You are 
recommended to ask the professional technical supports for help to set the filter 
parameters if necessary. 