User's Manual
Table Of Contents
- Chapter 1 System Requirement
- Chapter 2 Network Connection
- Chapter 3 Access to the Network Camera
- Chapter 4 Wi-Fi Settings
- Chapter 5 Live View
- Chapter 6 Network Camera Configuration
- Chapter 7 Network Settings- 7.1 Configuring Basic Settings
- 7.2 Configure Advanced Settings- 7.2.1 Configuring SNMP Settings
- 7.2.2 Configuring FTP Settings
- 7.2.3 Configuring Email Settings
- 7.2.4 Platform Access
- 7.2.5 Wireless Dial
- 7.2.6 HTTPS Settings
- 7.2.7 Configuring QoS Settings
- 7.2.8 Configuring 802.1X Settings
- 7.2.9 Integration Protocol
- 7.2.10 Bandwidth Adaptation
- 7.2.11 Network Service
- 7.2.12 Smooth Streaming
 
 
- Chapter 8 Video/Audio Settings
- Chapter 9 Image Settings
- Chapter 10 Event Settings- 10.1 Basic Events
- 10.2 Smart Events- 10.2.1 Configuring Audio Exception Detection
- 10.2.2 Configuring Defocus Detection
- 10.2.3 Configuring Scene Change Detection
- 10.2.4 Configuring Face Detection
- 10.2.5 Configuring Intrusion Detection
- 10.2.6 Configuring Line Crossing Detection
- 10.2.7 Configuring Region Entrance Detection
- 10.2.8 Configuring Region Exiting Detection
- 10.2.9 Configuring Unattended Baggage Detection
- 10.2.10 Configuring Object Removal Detection
 
- 10.3 VCA Configuration
 
- Chapter 11 Storage Settings
- Chapter 12 Playback
- Chapter 13 Picture
- Chapter 14 Application
- Appendix
Network Camera User Manual 
144 
Threshold: Range [5-100s], the threshold for the time of the objects left over in 
the region. If you set the value as 10, alarm is triggered after the object is left and 
stay in the region for 10s. 
9.  Drag the slider to set the sensitivity value. 
Sensitivity: Range [1-100]. Sensitivity stands for the percentage of the body part 
of an acceptable target that enters the pre-defined region. 
Sensitivity = 100 – S
1
/S
T
*100 
S
1
 stands for target body part that enters the pre-defined region. S
T
 stands for the 
complete target body.   
Example:  if  you  set  the  value  as  60,  a  target  is  possible  to  be  counted  as  an 
unattended  baggage  only  when  40  percent  body  part  of  the  target  enters  the 
region. 
Note: The Sensitivity of the detection is supported by certain models. Refer to 
actual display for details. 
10.  Repeat the above steps to configure other regions. Up to 4 regions can be set. You 
can click the Clear button to clear all pre-defined regions. 
11.  Click Arming Schedule to set the arming schedule. 
12.  Click Linkage Method to select the linkage methods. 
13.  Click Save to save the settings. 
  Configuring Object Removal Detection 
Purpose:   
Object removal detection  function  detects the objects  removed  from  the pre-defined 
region, such as the exhibits on display, and a series of actions can be taken when the 
alarm is triggered.   
Steps: 
1.  Enter the Object Removal Detection settings interface, Configuration > Event > 
Smart Event > Object Removal Detection. 