- Chapter 1 System Requirement
- Chapter 2 Network Connection
- Chapter 3 Access to the Network Camera
- Chapter 4 Wi-Fi Settings
- Chapter 5 Live View
- Chapter 6 Network Camera Configuration
- Chapter 7 Network Settings
- Chapter 8 Video/Audio Settings
- Chapter 9 Image Settings
- Chapter 10 Event Settings- 10.1 Basic Events
- 10.2 Smart Events- 10.2.1 Configuring Audio Exception Detection
- 10.2.2 Configuring Defocus Detection
- 10.2.3 Configuring Scene Change Detection
- 10.2.4 Configuring Face Detection
- 10.2.5 Configuring Intrusion Detection
- 10.2.6 Configuring Line Crossing Detection
- 10.2.7 Configuring Region Entrance Detection
- 10.2.8 Configuring Region Exiting Detection
- 10.2.9 Configuring Unattended Baggage Detection
- 10.2.10 Configuring Object Removal Detection
 
- 10.3 VCA Configuration
 
- Chapter 11 Storage Settings
- Chapter 12 Playback
- Chapter 13 Picture
- Chapter 14 Application
- Appendix
Network Camera User Manual 
112 
Max. Size: The maximum size of a valid target. Targets with larger sizes would 
not trigger detection. 
Min. Size: The minimum size of a valid target. Targets with smaller sizes would 
not trigger detection. 
7.  Select the direction for line crossing detection. And you can select the directions 
as A<->B, A ->B, and B->A. 
A<->B: The object going across the plane with both directions can be detected and 
alarms are triggered.  
A->B: Only the object crossing the configured line from the A side to the B side 
can be detected.  
B->A: Only the object crossing the configured line from the B side to the A side 
can be detected. 
8.  Click Stop Drawing when finish drawing. 
9.  Drag the slider to set the sensitivity value. 
Sensitivity: Range [1-100]. It stands for the percentage of the body part of an 
acceptable target that goes across the pre-defined line. 
Sensitivity = S1/ST*100 
S1 stands for the target body part that goes across the pre-defined line. ST stands 
for the complete target body.   
Example: if you set the value as 60, the action can be counted as a line crossing 
action only when 60 percent or more body part goes across the line.   
Note: The Sensitivity of the detection is supported by certain models. Refer to 
actual display for details. 
10.  Repeat the above steps to configure other lines. Up to 4 lines can be set. You can 
click the Clear button to clear all pre-defined lines. 
11.  Click the Arming Schedule to set the arming schedule. 
12.  Select  the  linkage  methods  for  line  crossing  detection,  including  Notify 
Surveillance  Center,  Send  Email,  Upload  to  FTP/Memory  Card/NAS,  Trigger 
Channel and Trigger Alarm Output. 
13.  Click Save to save the settings. 