Installation Instructions

2
Audible and Visual Alarm Indicators
When operang normally, a red LED adjacent to the Test buon will flash every 320 s. When smoke is detected, an internal sounder will acvate to alert occupants, and
the LED will flash rapidly. The sounder is a loud, pulsang alarm and produces a repeang Temporal 3 audible signal paern (0.5 s on, 0.5 s off for 3 cycles, followed by
1.5 s off, repeang).
Test/Hush BuonWhen there is no alarm present, hold the Test/Hush buon will acvate the smoke alarm to check its operaon. The alarm will sound and the LED will
flash rapidly. The unit will return to normal condion in about 10 s when the test is completed.
When the smoke alarm is in the Alarm condion, press the Test/Hush buon will hush the smoke alarm for approximately 11 min. The Hush feature should only be
used aer the cause of the alarm is known (such as normal cooking fumes). The Hush feature allows me for the smoke to clear. During the hush me, the LED will flash
twice every second. Aer the Hush me has expired, the smoke alarm will return to normal sensivity. If smoke is sll present in the unit, the alarm will re-acvate. The
Hush feature can be used repeatedly.
Smoke Chamber Fault
The detector monitors the condion of the smoke sensing chamber. If the smoke sensing chamber ceases to operate normally, the smoke alarm will emit a short
audible signal, then followed by a single Red LED indicator flash, repeang every 40 s. In this case, try vacuuming clean the detector to remove dust. If the condion
persists, replace the detector with a new unit.
Low Baery
When the baery is depleted, the detector will emit a short audible signal and the Red LED indicator flash, repeang every 40 s for at least 30 days. Interconnected
detector will also emit two short audible signals and the Red LED indicator will flash twice, repeang every 4 hours. When the Low Baery signal is given, replaced the
detector with a new unit.
Interconnecon
Wireless interconnecon allows up to 12 detectors to be connected together. Interconnected detector will acvate sounders on all units if any smoke alarm detector. In
this case, only the detector that detected smoke will flash the Red LED. This allows the home owner to quickly locate the cause of the alarm.
Local alarm memory
Aer alarm occurs, the green LED gives 3 flashes every 40 s up to 24 h, which stops flashing aer 24 hours. Any me before the next alarm, press the Test buon, the
detector shall emit 3 audible beeps every 1 s. Release of the Test buon shall reset the alarm.
Funcon
3
Enrollment
1. Log in the Hik-ProConnect, and select a site.
2. Select the AX PRO in the site.
3. Enter“Sengs-System Sengs” , and tap the "Enrollment Mode" buon to make the AX PRO enter the enrollemnt status.
4. Turn the power switch of the peripheral on to enrolled it to the control panel.
Enroll the Detector Locally
Register the Detector via APP
1. Log in the Hik-ProConnect, and select a site.
2. Select the AX PRO in the site.
3. Tap the “+” icon on the boom of the page, and scan the QR code to add the peripheral.
4. Turn the power switch of the peripheral on, and it will be automacally enrolled to the control panel.
1
2
xxxx
Device