Installation manual
Installation Manual of Network Camera
20
Figure 3-25 Cut Mounting Hole
3. Loosen the set screws with the hex key (supplied) to remove the lower dome; remove the dome
liner.
Figure 3-26 Remove the Lower Dome
4. Rotate the toggle to remove it from the toggle bolt; insert the bolt into the toggle bolt hole on
the dome module and use the screw driver to rotate the bolt slightly but not tightly; Reinstall
the toggle and push the dome module to the mounting hole on the ceiling with toggle bolts
aligned with the screw holes on the ceiling.