Installation manual
Installation Manual of Network Camera
3
Notes:
To reset the default parameters to the camera, you need to press and hold the RESET
button and power on the camera. After the power on of the camera, you must still press and
hold the Reset button for about 20 seconds.
The type of auto-iris interface is shown in Figure 2-2, and the definition of each pin is
shown below:
Figure 2-2 Auto-iris Interface
Table 2-2 Pins
DC-driven
1
Damp-
2
Damp+
3
Drive+
4
Drive-
Damp+, Damp-, Drive+ and Drive- pins are used when the auto-iris is driven by DC.
Camera wiring Diagram: