Note: The new limit stops will overwrite the existed ones by default.
5. You can clear the defined limit stops. Click IRIS+ to enter CLEAR STOPS and click IRIS+ again to
clear the stops.
Elevation Set
This function is for enabling or disabling the elevation angle in the tilt direction. The elevation angle
is -5º.
3.4.2 Configuring Presets
Purpose:
A preset is a predefined image position. For the defined preset, you can simply click the calling
button to view the desired image position.
TASK 1: Set a preset.
Steps:
1. Move the cursor to enter preset configuration submenu:
MAIN MENUS > DOME SETTINGS > PRESETS
PRESETS
PRESET NUM 1
[UNDEFINED]
<EDIT LABEL>
PRESET PTZ
CLEAR PRESET
BACK EXIT
Figure 3-14 Preset Configuration Menu
2. Choose the preset number:
Move the cursor to PRESET NUM and click IRIS+ to enter. Click the up and down buttons to
choose the preset number which needs to be edited. If the preset has been defined, the preset
label will be listed under the number; if it has not been defined, you will see [UNDEFINED]
under the number.
Notes:
There are up to 254 presets can be set for the speed dome.
The system-defined presets will be displayed on this submenu and they are not editable.
3. Edit the label of the preset.