User manual
Table Of Contents

User Manual of Analog Speed Dome
© Hikvision
38
If multiple alarms with different priorities are triggered at the same time, the dome only
responds to the alarm with the highest priority. If multiple alarms with the same priority are
triggered at the same time, then the dome will respond to each alarm according to the defined
alarm sequence.
3.6.2 Configuring Alarm Parameters
Purpose:
You can set the alarm related parameters following below instructions, including linkage action
interval, alarm duration and dome activity resumption.
Steps:
1. Enter the alarm parameter configuration menu:
MAIN MENUS > DOME SETTINGS > ALARMS > ALARM SETTING
2. Configure the interval of the alarm sequence.
When more than one alarm of the same priority occurs at the same time, the speed dome will
respond to one alarm first and then respond to the next one after the user-defined interval. You
can set the on ALARM SEQUENCE submenu from 1 to 200 seconds.
3. Configure the alarm rest delay.
If there’s a linkage action has already been triggered by an alarm input, the speed dome will
only respond to the input from the same channel again after the user-defined reset delay time.
This is the rest time that the speed dome considers an alarm to be active when it’s physically
cleared. You can set the ALARM REST DELAY from 0 to 300 seconds.
4. Resume the dome activity.
You can set ALARM RESUME to ON to enable the speed dome to resume its previous activity
after the triggered actions finished.
Notes:
If the speed dome is moving when a linkage action is triggered, it will stop at the current
position and resume from this position after the linkage action finishes.
The speed dome can be configured to resume the PTZ positions, focus and iris value.
3.6.3 Configuring Auxiliary Alarm Output
Purpose:
An auxiliary output is a configurable alarm output interface on the speed dome back box which can
connect and trigger another alarm device to operate.
Steps:
1. Enter the alarm auxiliary output configuration submenu:
MAIN MENUS > DOME SETTINGS > AUXS