Thermal Image Scope User Manual
Thermal Image Scope User Manual Legal Information © 2020 Hangzhou Microimage Software Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the HIKMICRO website (www.
Thermal Image Scope User Manual RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
Thermal Image Scope User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Thermal Image Scope User Manual 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.
Thermal Image Scope User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Danger Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury. Caution Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.
Thermal Image Scope User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. Laws and Regulations ● Use of the product must be in strict compliance with the local electrical safety regulations. Transportation ● Keep the device in original or similar packaging while transporting it. ● Keep all wrappers after unpacking them for future use.
Thermal Image Scope User Manual ● It is recommended to reboot the device every 2 hours when using it to ensure the device performance. Using Environment ● Make sure the running environment meets the requirement of the device. The operating temperature shall be -20°C to 55°C (-4°F to 131°F), and the operating humidity shall be 95% or less. ● DO NOT expose the device to high electromagnetic radiation or dusty environments. ● DO NOT aim the lens at the sun or any other bright light.
Thermal Image Scope User Manual Chapter 1 Overview 1.1 Device Description The thermal image scope is equipped with high-sensitivity IR detector, and adopts advanced thermal imaging technology, to get clear view in poor visibility or dark environment. It helps to aim at the target, and measuring the distance. It can aim at the moving target and meets the outdoor condition. The device can be widely used in patrolling, searching and rescuing, hiking, hunting, and travel, etc. 1.
Thermal Image Scope User Manual 1.3 Appearance 1.3.
Thermal Image Scope User Manual Shutter ● Press: Correct Non-uniformity of Display 1.3.
Thermal Image Scope User Manual Figure 1-4 Interfaces of Thermal Camera with Daylight Scope Table 1-2 Interface Description Component Function Objective Lens Adjust the distance between the lens and the sensor to view the target much clearer. Focus Ring Adjust the sight view. Bolt Loosen the bolt to install the batteries. Knob Secure the device to the gun base. Data Exchange Interface Connect with the output cable. Transfer Ring Connect with a daylight scope.
Thermal Image Scope User Manual Chapter 2 Preparation 2.1 Cable Connection Connect the device and power adaptor with a type-C cable to power on the device. Alternatively, connect the device and PC to export files. Figure 2-1 Cable Interface 2.2 Install Battery Insert the batteries into the battery compartment. Steps 1. Rotate the knob anticlockwise to loosen it. Figure 2-2 Loosen Knob 2. Make sure the battery's positive terminal and negative terminal are installed correctly.
Thermal Image Scope User Manual Figure 2-3 Install Batteries 3. Rotate the knob clockwise to tighten it. Take the battery away if the device is not used for a long time. 2.2.1 Select Battery Type You can change the battery type according to your need. Select the correct battery voltage in the device menu. Steps 1. In the view mode, hold 2. Select , and press to show the menu. to switch the voltage. 2.3 Secure Device Before You Start ● Turn off the device first.
Thermal Image Scope User Manual Figure 2-4 Tighten Screws 3. Tighten the knobs to secure the device as arrow 2. Figure 2-5 Secure the Device 2.4 Change Eyepiece The device can be used as a handheld observational camera or a clip-on scope. You can change the eyepiece to realize different use of the device. Steps 1. Rotate the fixing ring of eyepiece anticlockwise to remove it. 2. Align the eyepiece with the grooves of device, and rotate the eyepiece clockwise to tighten it.
Thermal Image Scope User Manual Figure 2-6 Change Eyepiece 2.5 Install Daylight Scope You can use the device together with a daylight scope to view the target clear in daytime. Steps 1. Install the daylight scope into the transfer ring as arrow 1. 2. Lock the buckle to fix the daylight scope as arrow 2. Figure 2-7 Install Daylight Scope 2.6 Power On/Off Power On When the battery is enough, press to power on the device.
Thermal Image Scope User Manual Power Off When the device is turned on, hold for 2 seconds to power off the device. 2.7 Menu Description When the device is turned on, press to display the OSD menu. ● Press to move the cursor up. ● Press to move the cursor down. ● Press to move the cursor left. ● Press to move the cursor right. ● Press to confirm.
Thermal Image Scope User Manual Chapter 3 Image Settings 3.1 Adjust Diopter Steps 1. Power on the device. 2. Open the lens cover. 3. Hold the device and make sure the eyepiece covers your eye. 4. Adjust the focus ring until the OSD text or image is clear. Figure 3-1 Adjust Focus Ring Note When adjusting diopter, DO NOT touch the surface of lens to avoid smearing the lens. 3.2 Adjust Brightness In the menu mode, select and press to adjust brightness.
Thermal Image Scope User Manual 3.4 Select Scene You can select proper scene according to actual using scene to improve the display effect. Steps 1. Hold to go to the menu. 2. Select and press to switch scene. – refers to recognition mode and is recommended in normal scene. – refers to jungle mode and is recommended in hunting environment. 3. Hold to save settings and exit. 3.5 Set Palettes You can select different palettes to display the same scene in different effects. Press switch palettes.
Thermal Image Scope User Manual Red Hot The hot part is red-colored in view. The higher the temperature is, the redder the color is. Fusion From high temperature to low temperature, the image is colored in from white, yellow, red, pink to purple.
Thermal Image Scope User Manual 3.6 Correct Defective Pixel The device can correct the defective pixels on the screen which are not performed as expected. Steps 1. Hold 2. Select 3. Press 4. Press to show the menu. . , , , and to move the cursor to the position of dead pixel. to correct the dead pixel. 3.7 Flat Field Correction This function can correct non-uniformity of display. Steps 1. Hold to go to the menu. 2. Select and press to switch FFC mode.
Thermal Image Scope User Manual Note When you select Upper Right as PIP type, the OSD will be blocked. Figure 3-3 Set Picture in Picture Mode 4. Hold to exit. If digital zoom is enabled, the PIP view also zooms. If the digital zoom ratio exceeds 4, the PIP does not zoom. 3.9 Adjust Digital Zoom You can zoom the image by using this function. Press in the view mode, the live view switches between 1 ×, 2 ×, 4 ×, and 8 ×. Note This function varies according to different camera models. 3.
Thermal Image Scope User Manual Chapter 4 Highest Temperature Tracking The device can detect the highest temperature spot in the scene and mark it on display. In the menu, select and press to mark the spot of highest temperature. When the function is enabled, displays in the spot of highest temperature. When the scene changes, the moves.
Thermal Image Scope User Manual Chapter 5 Aiming Point Settings 5.1 Correct Range Table Enable the range table to aim at the target. Steps 1. In the view mode, hold to show the menu. 2. Select . A crosshair shows in the center of the view. 3. Press , or to select the range table type. Then press to confirm. 4. Press , , , and to move the crosshair position. The coordinate shows the current position of the crosshair. 5. Hold to save and exit. 5.
Thermal Image Scope User Manual 5.3 Set Crosshair Color The function can change the color of the crosshairs in range table correction display, trajectory correction display, and distance measurement display. Before You Start Enable range table correction first. Steps 1. In the view mode, hold to show the menu. 2. Select and press to switch the color of crosshair. White, Green, and Red are selectable. 3. Hold to save and exit.
Thermal Image Scope User Manual Chapter 6 Measure the Distance The device can detect the distance between the target and the observation position. Before You Start When measuring the distance, keep the hand and the position steady. Otherwise, the accuracy may be affected. Steps 1. Hold to show the menu. 2. Select and press to go to the setting interface. 1) Press or to select the target from Deer, Wolf, Bear, and Custom. 2) Set the target height. Note The available height ranges from 0.1 m to 9.9 m.
Thermal Image Scope User Manual Figure 6-2 Set the Edge of Target Bottom Result The left top of the image displays the distance measurement result and the height of the target. Figure 6-3 Measurement Result Note Go to distance measurement interface, and press measuring target.
Thermal Image Scope User Manual Chapter 7 Picture and Video You can manually record video or capture picture when displaying live view. 7.1 Capture Picture On the main live view page, press to capture picture. Note ● When capturing succeeds, the image freezes for 1 second and a prompt shows on the display. For exporting captured pictures, refer to Export Files. 7.2 Record Video Steps 1. In the main live view, hold and start recording.
Thermal Image Scope User Manual 7.3 Export Files This function is used to export recorded videos and captured pictures. Before You Start Turn off hot spot function. Steps 1. Connect the device and PC with cable. Note Make sure the device is turned off when connecting the cable. 2. Open computer disk and select the disk of device. Go to DICM → 100EZVIZ. 3. Select and copy the files to PC. 4. Disconnect the device from your PC. Note ● The device displays images when you connect it to PC.
Thermal Image Scope User Manual Chapter 8 Client Software Connection Connect the device to the T-Vision APP via hot spot, then you can capture picture, record video, or configure parameters on your phone. Steps 1. Hold to show the menu of device. 2. Press to enable hot spot function. 3. Turn on the WLAN of your phone and connect to the hot spot. ● Hot Spot Name: HIK-IPTS Serial No. ● Hot Spot Password: the last 9 digits of serial No. 4.
Thermal Image Scope User Manual Chapter 9 CVBS Output View the device image on the display unit for details. Before You Start Connect the device to the display unit via CVBS interface of the aviation plug. Steps 1. Hold to show the menu. 2. Select CVBS, and press to switch on CVBS.
Thermal Image Scope User Manual Chapter 10 Language Settings Go to the device menu, select , and press to switch the device language.
Thermal Image Scope User Manual Chapter 11 Maintenance This part introduces the operation of checking device information, upgrading device, and restoring to defaults, etc. 11.1 View Device Information Steps 1. Hold 2. Select to show the menu of device. , and press . You can view the device information such as version, and serial No. 11.2 Upgrade Device Before You Start Please get the upgrade package first. Steps 1. Connect the device to your PC with cable. 2.
Thermal Image Scope User Manual Chapter 12 Frequently Asked Questions 12.1 Why is the monitor off? Check whether the device is off-battery. Check the monitor after charging the device for 5 minutes. 12.2 The image is not clear, how to adjust it? Adjust the diopter adjustment knob until the image is clear. Refer to section Adjust Diopter. 12.3 Capturing or recording fails. What's the problem? Check the following items. ● Whether the device is connected to your PC.
Thermal Image Scope User Manual Chapter 13 Appendix 13.1 Device Command Scan the following QR code to get device common serial port commands. Note that the command list contains the commonly used serial port commands for Hikmicro thermal cameras. 13.2 Device Communication Matrix Scan the following QR code to get device communication matrix. Note that the matrix contains all communication ports of Hikmicro thermal cameras.
UD20125B