5. Press
.
Note
Only one line is supported.
The max. temperature, low temperature, and average temperature of line (e.g. L1) displays L1
Max: XX Min: XX Avg: XX. The real-me temperature trend chart will display.
4.3.3 Set Frame Rule
Steps
1. Select .
2. Press to generate a default frame.
3. Press , , , and to move the frame up/down/le/right.
4. Press to enlarge the frame, and press to contract the frame. Or you can drag the corner
of the frame on touch-screen to enlarge or contract the frame.
5. Press .
The max. temperature, low temperature, and average temperature of frame (e.g. S1) displays S1
Max: XX Min: XX Avg: XX.
6. Repeat step 1 to 5 to set other frames.
Note
At most three frames are supported.
4.3.4 Delete Rules
Tap and press to clear all temperature rules. Or tap and choose the single rule you want
to delete.
4.4 Set Temperature Alarm
Set the alarm rules and the device will alarm when the temperature triggers the rule.
Before You Start
Set the
palee.
Steps
1. Select
Palees from the main menu.
2. Tap the icons to select an alarm rule type.
Handheld Thermography Camera User Manual