User's Manual

Note
You can go to Local Sengs → Device Sengs → Device Inializaon → Measurement Tool
Inializaon to inialize the temperature measurement parameters.
4.1.1 Set Unit
Go to Local Sengs → Device Sengs → Unit to set the temperature unit and distance unit.
Note
You can go to Local Sengs → Image Sengs → Display Sengs to enable/disable the
temperature display.
4.2 Set Temperature Range
Set a temperature secon and the palee only works for targets within the temperature secon.
You can adjust the temperature range.
Steps
1. Select
from the main menu.
2. Select auto adjustment or manual adjustment .
Auto
Adjustment
Select , and press . The device adjusts temperature range
parameters automacally.
Manual
Adjustment
Select , and press .
Press or to select the max. temperature, min. temperature, or
both. You can also tap on the screen to select the max. temperature or
min. temperature.
Press or adjust the temperature value. You can also tap on the
arrows on the right side of the screen to adjust the temperature value.
3. Press to exit.
4.3 Set Thermography Rule
You can set thermography parameters to improve the accuracy of temperature measurement.
Steps
1. Select
from the main menu.
2. Set the point, line, or frame rules. See gure below.
Handheld Thermography Camera User Manual
20