User Manual

BILL COUNTER
ADDITIONAL FUNCTIONS
7
1. Chain Notes Detection
Serving as a supplementary function, the chain-note detection can be activated
when the unit is powered up. If the machine detects a chain-note during counting, it
will stop and emit a beeping sound and the counting display will show the message
‘E-9’ (alerting the user to the presence of a chain-note bill). Remove the bill and press
‘RESTART’ to continue counting.
PLEASE NOTE: The suspicious bill will be added to the counted quantity.
2. Half-Note Detection
By default, serving as a supplementary function, the half-note detection can be
activated when the unit is powered up. If the machine detects a half-note during
counting, it will stop and emit a beeping sound and the counting display will show
the message ‘E-1’ (alerting the user to the presence of a half-note bill). Remove the
suspicious bill and press ‘RESTART’ to continue counting.
PLEASE NOTE: The suspicious bill will be added to the counted quantity.
3. Double-Note Detection
Hold ‘RESTART’ button for 5 seconds until the counting display window shows ‘OP-A’
and the ‘BATCH’ display windows shows one digit of the number ’00-10’. Press the ‘+’
button to select ‘OP-C’ in the counting display window. Press the ‘–‘ button to select
‘IR’ (Infrared) sensitivity (the higher the number setting, the higher the ‘IR’ sensitivity).
Select the ‘IR’ at ’00’ to stop this function.
4. Bill Feeding Mode
Hold ‘RESTART’ button for 5 seconds until the counting display window shows ‘OP-A’
and the ‘BATCH’ display window shows one digit of the number ’00-10’. Press the ‘+’
button to select ‘OP-E’ in the counting display window. Press the ‘–‘ button to select
‘YES’ or ‘NO’ as required (‘YES’ activates the auto feed function and ‘NO’ for manual
feed). For manual feed mode, the machine will only start counting by pressing the
‘RESTART’ button after placing bills in the feeding hopper.
5. Size Detection
Hold ‘RESTART’ button for 5 seconds until the counting display window shows ‘OP-A’
and the ‘BATCH’ display window shows one digit of the number ’00-10’. Press the ‘+’
button to select ‘OP-D’ in the counting display window. Press the ‘–‘ button to select
‘YES’ or ‘NO’ as required (‘YES’ activates the size detection function and ‘NO’ for off).
6. Suspicious Bill Inclusion
To set whether or not a suspicious bill is included in a count, hold ‘RESTART’ for 5
seconds until the counting display window shows ‘OP-A’ and the ‘BATCH’ display
window shows one digit of the number ’00-10’. Press the ‘+’ button to select ‘OP-D’ in
the counting display window. Press the ‘–‘ button to select ‘YES’ or ‘NO’ as required
(‘YES’ activates the counting function while detecting a dubious bill and ‘NO’ for off).