Datasheet
Switching Power Supply Specifications
Page 5
3. Output characteristics
3.1 Normal Operation Output
Output
Voltage
Load
MIN
Range
MAX
Peak Regulation
Ripple & Noise
P-P Max.
1. +5V
0.2A 22.0A
±5% 50mV
2. +3.3V
0.1A 22.0A
±5% 50mV
3. +12V
0.6A 56.25A
±5% 120mV
4. -12V
0.0A 0.3A
±10% 120mV
5. +5Vs
0.0A 2.5A
3.5A ±5% 50mV
z Maximum continuous total DC output power should not exceed 750W.
z Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not exceed 130W.
z Maximum combined load on 12V outputs shall not exceed 675W.
NOTE:
Noise test should be measured with 20 MHz bandwidth frequency oscilloscope. The output terminal
shall add a tantalum capacitor of 10uF in parallel with a ceramic capacitor of 0.1uF.
3.2 Remote On/Off Controlled mode
The PSON# signal is required to remotely turn on/off the power supply, PSON# is an active
low signal that turns on the output power rails. When this is not pulled low by the system, or
left open, the outputs (except the +5VSB) turn off. This signal is pulled to a standby voltage
by a pull-up resistor internal to the power supply.
TTL level "H" 2.0 V - 5.25 V
"L" 0.0 V – 1.0 V
3.3 Regulation
The cross regulation defined as follows, the output regulation should be within the specified
range.
Load +5V +3.3V +12V -12V +5Vsb
Light Load.
2.86 A 2.86 A 10.28 A 0.05 A 0.46A
Typical Load
7.15 A 7.15 A 25.69A 0.14 A 1.14 A
Full Load
14.31 A 14.31 A 51.38A 0.27 A 2.28A