Technical Data

High Performance Cement by Quikrete
®
www.highperformancecement.com • (800) 388-4338
FastSet
Concrete Mix
Table 1 Typical
Physical Properties
Setting time, ASTM C191
Final 25 - 45 min.
Slump, inches (mm), ASTM C928
3-4 (76-102)
Compressive strength, ASTM C39
3 hours 3000 psi (20.7 MPa)
24 hours 5000 psi (34.5 MPa)
7 days 6000 psi (41.3 MPa)
28 days 7000 psi (48.3 MPa)
Shrinkage, ASTM C928
28 days in air (typical) > -0.03
28 days in water (typical) < +0.01
Scaling Resistance, ASTM C672
Visual 2
Do not use more than 1 gal (3.8 L) of mixing water per bag
Mixing must be completed in 3 - 4 minutes
Temperature of Water
Because of the rapid setting time, special precautions
must be taken as set times will fluctuate in extremely
hot or cold weather. Use cold water or water mixed
with ice cubes in severely hot weather. Use hot water
when mixing in severely cold weather.
Placing
The forms, hole or sub-base should be thoroughly
dampened
Fill the forms completely working from one end to
the other. Avoid partial depth lifts which could result
in cold joints
Consolidate the material using hand tamping and/or
chopping with a shovel. It is particularly important to
compact around the edges of the forms or patches
Screed the surface, and then apply a trowel or
broom finish as desired
Curing
FastSet
Concrete Mix is often placed in service within
a few hours after it sets, so conventional moist curing
methods are not practical. Sealing the surface with
QUIKRETE
®
Concrete Cure and Seal – Satin Finish
(No. 8730) after the concrete has hardened will ensure
proper curing and provide an additional measure
of protection against salt and water penetration.
Under hot, dry and windy placing conditions, all
concrete tends to lose moisture unevenly and may
develop plastic shrinkage cracks. The use of sheeting,
monomolecular films (either sprayed or rolled on), as
well as application of a very fine fog spray of water,
has been quite successful in arresting shrinkage
cracking.
Precautions
During extremely hot or dry conditions, cold water
should be used to maintain mix at a moderate
placement temperature
Mix no more than can be used in 20 minutes
Warranty
The QUIKRETE
®
Companies warrant this product
to be of merchantable quality when used or applied
in accordance with the instructions herein. The
product is not warranted as suitable for any purpose
or use other than the general purpose for which it is
intended. Liability under this warranty is limited to the
replacement of its product (as purchased) found to
be defective, or at the shipping companies’ option,
to refund the purchase price. In the event of a claim
under this warranty, notice must be given to The
QUIKRETE
®
Companies in writing at: One Securities
Centre, 3490 Piedmont Road, Suite 1300, Atlanta, GA
30305. This limited warranty is issued and accepted
in lieu of all other express warranties and expressly
excludes liability for consequential damages.
Refer to www.highperfomancecement.com for
the most current technical data, MSDS, and guide
specifications.