User Manual

HF-LPB200 Low Power WiFi Module User Manual
Shanghai High-Flying Electronics Technology Co., Ltd
www.hi-flying.com
- 42 -
Query Operation
AT+MID<CR>
+ok=<module_id><CR>< LF ><CR>< LF >
Parameters:
module_id: Module ID information;
HF-LPB200;
Notes: User can set this parameter through AT+WRMID.
5.2.2.6. AT+VER
Function: Query module software version information;
Format:
Query Operation
AT+VER<CR>
+ok=<ver><CR>< LF ><CR>< LF >
Parameters:
ver: Module software version information;
5.2.2.7. AT+RELD
Function: module restore to factory default setting;
Format:
Set Operation
AT+ RELD<CR>
+ok=rebooting<CR>< LF ><CR>< LF >
When operate this command, module will restore to factory default setting and reboot.
5.2.2.8. AT+Z
Function: Re-start module;
Format:
AT+ Z<CR>
5.2.2.9. AT+H
Function: Help;
Format:
Query Operation
AT+H<CR>
+ok=<command help><CR>< LF ><CR>< LF >
Parameters:
command help: command introduction;
5.2.2.10. AT+CFGRD
Function: Batch Read User Configure Parameters;
Format:
Query Operation
AT+CFGRD<CR>